5. Provide a longitudinal section of the access driveway extending from the
centreline of the existing formation of Olivine Lane and including the
required road widening and kerb line. The longitudinal section must
demonstrate that vehicles will not bottom out or scrap (the driveway and
road pavement) when entering or exiting the site and be in accordance with
AS/NZS2890.1 for a B99 vehicle.
A Preliminary engineering plan is included which include a 2m road widening, stormwater
details and manhole locations. The extensions are to transition in with the adjoining road
alignment and includes a 5m/6m wide crossover with maximum grades of 1 in 5 for 5.4m
within the site.
This code assessable application is for MCU only and further detailed plans are to be
incorporated as part of the subsequent Operational Works and REC approvals. In this
regard, any further works Council require shall be conditioned as part of this development
permit.
6. Provide details of the alignment and levels of the existing sewer main on the
site, and a written confirmation from Unitywater that states that the proposed
floor level is sufficient to provide fall to connect to the existing sewer main.
Further detailed sewer investigations have been undertaken by the applicant and it has
been recommended the downstairs bathrooms include a small pump to connect into the
Unitywater infrastructure. These details are provided on the preliminary engineering plans.
7. Submit a landscape concept plan which addresses Acceptable Outcome
AO10.1.
A landscape concept plan is included, providing for landscaping around the perimeter of
the site and between buildings. This code assessable application is for MCU only and
further detailed plans are to be incorporated as part of the subsequent Operational Works
and REC approvals. In this regard, any further works Council require shall be conditioned
as part of this development permit.
8. Provide details around location and type of any existing trees proposed to
be removed to facilitate the development.
The existing mature exotic trees within the middle of the site are proposed to be removed
to accommodate the development. A photo of the existing trees to be removed is included
below.
Page 2 of 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
response to information request MCU.pdfRelated documentApplication case desk ↗
About this file
- File size
- 791 KB (small file)
- File type
No other editions are linked here.