and suitable founding materials. It is our opinion that an appropriately designed micropile or CFA pile
structure will provide acceptable factors of safety against global slope instability.
It is understood that underground services will be installed via HDD. Unsupported open trenching for the
installation of services should not be undertaken.
6.2 Retaining Wall Design and Parameters
Retaining walls must be founded as described in Section 6.3 and may be designed using the parameters in
Table 3, and in accordance with AS4678-2002 Earth retaining structures.
Allowance should be made for construction loading, up-slope footing loadings, the effects of sloping ground
(if not supported on piles), hydrostatic loads, and backfill compaction stresses.
Table 3: Retaining Structure Design Parameters.
Unit Friction
Lateral Earth Pressure Coefficient
Weight Angle
Retained Material Ka Ko
(t/m3) (Degrees) (Cantilever (Non yielding Kp
Wall) wall)
Loose Sand 1.7 30 0.3 0.5 3.0
Medium Dense Sand 1.8 34 0.25 0.45 3.4
Dense sand 1.9 38 0.2 0.4 4.2
Stiff (or stiffer) Clay 1.8 27 0.4 0.6 2.6
Engineered Fill (future) 1.9* 34* 0.28* 0.4* 3.5*
Note: *Preliminary only; depends on fill material type and level of compaction.
Positive permanent drainage must be installed behind all walls unless they are designed for development of
full hydrostatic pressures.
6.3 Foundation Design and Parameters
6.3.1 High-level footings
Where suitable stiff (or stiffer) clay is present at shallow depth (i.e. proposed Lot 3), the proposed buildings
may be supported on conventional high-level strip or pad footings. Such footings may be designed using an
allowable bearing pressure of 100 kPa.
To achieve the design recommended pressures, footing excavations must be dry and cleaned of any loose,
disturbed or saturated materials prior to pouring concrete.
All existing and proposed footings should found such that they are not adversely affected by any adjacent
excavations, batter slopes, trenches, or retaining walls that are not designed to support building or fill loads.
To minimise the potential for any adverse interaction effects, footings should found at least below a plane
extending 1 m horizontally from the base of trenches/batter slopes/excavations/ retaining walls, then rising
up at 1V:1H. This requirement is illustrated in the following diagram.
7
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Response to Info Request - Attachment 5 - Geotechnical Report MCU18-0015 & RAL18-0001.pdfRelated documentApplication case desk ↗
About this file
- File size
- 8.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.