Appendix B Code Assessment Report - 14-16 Mary Street, Noosaville - Bounce Hostels 15.6.2018
Attached to the e-mail Visitor Accommodation Type 4 Conventional - 122 beds (Architectural Plans & Code Assessment Report) MCU18/0102.msg.
accordance with Council’s Standard Drawing requirements. Refer to Engineering report and plan17699-
SK001 prepared by TOD’s Consulting in
Appendix F of this report.
O3 In commercial zoned areas, the number of driveways S3.1 Design of multi-tenanted developments in commercial Not Applicable
across pedestrian footpaths is minimised. zoned areas include shared driveways and parking areas; A residential use (Visitor Accommodation -
AND Type 4 Conventional) is proposed in the
Business Centre Zone.
S3.2 Driveways are located so they abut existing driveways Not Applicable
of adjoining development where practicable and reciprocal A residential use (Visitor Accommodation -
easements are created to reduce the sealed driveway width. Type 4 Conventional) is proposed in the
Business Centre Zone.
O4 Vehicular access does not adversely impact on the S4.1 Footpath and kerb crossings are located clear of Complies
capacity, operations and maintenance of the existing existing stormwater inlet structures, water and sewerage The proposed crossovers will be
infrastructure; AND infrastructure fittings, any other exiting utility infrastructure, appropriately designed and sited as to not
existing landscaping and vegetation. adversely impact upon Council’s existing
infrastructures.
O5 Vehicular access does not adversely impact on the S5.1 Vehicular access avoids disturbance to the tree Complies
health and integrity of existing landscaping or native protection zone of trees on public land. The site has been previously cleared and no
vegetation, where possible. vegetation of ecological significants exists
on site.
O6 Driveway run-off is filtered prior to leaving the S6.1 For— Complies
premises. a) Ancillary dwelling unit, Multiple housing Type 2 if less It is proposed to install a grated drain at the
than 5 carparking spaces, Visitor accommodation Type 1 and base of the ramp to collect runoff. This will
Homebased business Type 3—the driveway is formed to be discharged into a sealed storage tank
drain to landscaped areas; and and pump below the basement car park
b) for other uses—grease and oil arrestors or stormwater which would be set up to pump to the
quality improvement devices are incorporated into the street during a rainfall event
design to treat run-off prior to run-off exiting from the
premises.
Table 14-50 — Carparking and manoeuvring
14.113 Carpark design and layout
O7 Sufficient carparking is provided to accommodate S7.1 The number of parking and loading bays is not less than Complies
the number and type of vehicles likely to be generated the minimum number specified in Table 14-51 Vehicle Sufficient car parking spaces are provided
by the development having regard to the specifics of the Parking Requirements; in the basement carpark. Refer to DA.03
use including— within Appendix A.
14-16 Mary Street, Noosaville 36