                      Earthworks and Retaining Walls
               32.    All earthworks and associated batters/retaining structures, both above and below ground
                      level, both temporary and permanent, must be contained entirely within the subject site
                      unless written permission from the respective landowner(s) is provided to Council. All
                      earthworks must be undertaken in accordance with the provisions of Australian Standard
                      AS3798: Guidelines on Earthworks for Commercial and Residential Developments.
               33.    Where the development involves excavation or filling over, or adjacent to, drainage, water
                      supply or sewerage infrastructure, all access chamber surface levels must be adjusted to
                      provide a freeboard of 100mm above the finished ground surface level.
               34.    All retaining walls must be designed and constructed in accordance with the planning scheme
                      and must be certified by an RPEQ where exceeding 1.0m in height. All retaining walls that
                      are publicly accessible and exceed 1.0m in height must be fitted with a commercial grade
                      safety fence.
                      Landscaping Works
               35.    The development site must be landscaped. The works must be undertaken in accordance
                      with an Operational Works approval and the Noosa Plan for that specific area and must
                      include in particular:
                      a.      the works shown on the reference plans.
                      b.      The area between the southern boundary and the proposed footpath, landings, and
                              stairs must be landscaped. The works must include the provision of tall tree species
                              capable of growing to a minimum of 5 metres tall, to assist in softening the built form
                              of the development when viewed from neighbouring properties and Councils footpath.
                      c.      Landscaping plans that substitute Nandina domestica for a variety of shrubs from the
                              Noosa Plan 2020 PSP 2 – Landscape.
                      d.      The area between the swimming pool and rear fence is to be screened by a 3.5 metre
                              wide buffer densely planted with trees and shrubs.
                      e.      Landscape plans that incorporate additional trailing vines that can achieve the
                              architectural intent of the submitted renders.
                      f.      Vegetated screening of any electrical transformers, bin storage areas and the like from
                              the road frontage
                      g.      Provision of 1 street tree within the road reserve for every 8 metres of road frontage
               36.    All landscape works must be established and maintained in accordance with the approved
                      design for the life of the development, and in a manner that ensures healthy, sustained and
                      vigorous plant growth. All plant material must be allowed to grow to full form and be
                      refurbished when its life expectancy is reached.
               37.    The existing trees located within neighbouring properties must be assessed by a qualified
                      person* and retained and protected in accordance with an Arborist Report (or part thereof)
                      prepared by a qualified person* and endorsed through an Operational Works approval.
               38.    All planting areas on the eaves must be planted and maintained at all times, with replacement
                      planting undertaken promptly where plants fail or do not have a healthy and vigorous growth.
               39.    All planting areas on the northern side of the Unit 5 - Roof terrace is to contain suitable dense
                      screening and landscaping to ensure a minimum height of 2.0 metres. The landscaping is
                      to ensure overlooking is minimised and visual privacy is maintained to adjacent roof terraces
                      and private open spaces.
                      Waste Management
               40.    A waste storage area must be designed and maintained in accordance with Planning
                      Scheme Policy PSP9 Waste Management and the Noosa Plan’s Waste Management Code.
                      The waste storage area must be:

                                                                                                       Page 23 of 28

Document Set ID: 23409043
Version: 7, Version Date: 18/08/2025

Used in these records

About this file

File size
5.5 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Delegated Report - Code - Planning MCU24 0153 & OPW24 0202 (As Published).pdf · 5.5 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.