MCU14/0106 & OPW15/0001 Town Planning Report & Appendix A Code Compliance

of 239

Page text shows just the words. Original shows the document exactly as it was published.

Original PDF page 115, section 1. The text section number identifies this passage in the reader.

                                                                                                                                                                                  Town Planning Report
                                                                                                   28 Eenie Creek Road, Noosaville and parts of the road reserves of Hofmann Drive and Walter Hay Drive



A2 – Business Uses Code
Table 14-5 New Business Uses Within Existing Buildings in Established Centre
R1 – R9 - Not Applicable – The provisions in Table 14-5 do not apply to land in the Shire Business Centre Zone, as the Noosaville Locality Code provides
specific provisions relating to development on land in the Shire Business Centre Zone.


Table 14-6 New Industrial Uses Within Existing Buildings Within Existing Industrial Estates
R10 – R16 - Not Applicable – The proposed development is not an industrial use.


Table 14-7 Estate Sales Offices
R17 - Not Applicable – The proposed development is not an estate sales office.


Table 14-8 For all Business Uses
 Specific Outcome                                         Probable Solution                                                         Response
 14.16 Effects of use
 Electricity infrastructure
 O18      The development does not adversely             S18.1     No solution provided                                             R18.1 Alternative Solution (as no Probable Solution is provided)
          impact on existing or future electricity                                                                                  The proposed development will be referred to Energex Limited as an
          supply infrastructure;                                                                                                    Advice Agency. The Engineering Report prepared for the proposal
                                                                                                                                    (refer to Appendix E) indicates that sufficient electricity
                                                                                                                                    infrastructure exists and can be provided to allow electricity to be
                                                                                                                                    supplied to the proposal without any significant impact on the
                                                                                                                                    existing network.
 O19      All uses and works maintain an adequate        S19.1     Development for uses adjacent to or within 50m of an             R19.1 Will Comply
          safe distance from electrical infrastructure             existing electricity substation incorporates noise attenuation   The proposed development is not located within the vicinity of an
          including substations, overhead powerlines,              measures to mitigate noise impacts;                              Energex substation. The proposal will be appropriately designed to
          power poles and transformers.                            AND                                                              mitigate any negative impacts associated with any private electricity
                                                                                                                                    infrastructure required to be provided (refer to Appendix E).
                                                         S19.2     Buildings and structures (including swimming pools, sheds,       R19.2 Complies
                                                                   tennis courts and outbuildings) are not constructed under        Electricity infrastructure across the site is protected by easements.
                                                                   overhead electricity transmission lines, or within electricity   The proposal will also be referred to Energex Limited as an Advice
                                                                   easements.                                                       Agency. The proposed expansion is not located within the vicinity of
                                                                                                                                    existing electricity infrastructure.
 Noise




December 2014                                                                             Cardno HRP                                                                                           A34
Log in to download the original file

MCU14_0106 & OPW15_0001 Town Planning Report & Appendix A Code Compliance.pdf · 3.7 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.