Original source · versioned page text
MCU14/0106 & OPW15/0001 Town Planning Report & Appendix A Code Compliance
Original PDF page 134, section 1. The text section number identifies this passage in the reader.
Town Planning Report
28 Eenie Creek Road, Noosaville and parts of the road reserves of Hofmann Drive and Walter Hay Drive
A4 – Biodiversity Overlay Code
A response to the Biodiversity Overlay Code is provided in section 6.2 and Appendix R of the State and Local Government Ecological Assessment Report provided
as Appendix F to the Town Planning Report.
A5 – Natural Hazards Overlays Code
Table 13.8 Landslide hazard areas
R1 – R3 - Not Applicable – The proposed development is not an located in a landslide hazard area.
Table 13.9 Bushfire hazard areas
A response to Table 13.9 of the Natural Hazards Overlay Code is provided in section 5.1 of the Bushfire Assessment Report provided as Appendix H to the Town
Planning Report.
Table 13.10 Flood Hazard areas
The below code response has been prepared by Cardno HRP and Cardno Engineering. In addition to the Town Planning Report, reference should be made to the
Engineering Report (Appendix E) in reading this code response.
Specific Outcome Probable Solution Response
13.33 Effects of use and subdivision
Safety and floodplain function
O14 The proposed use does not compromise the S14.1 The use does not result in an increase in the number of R14 Not Applicable
safety of people or property from floods up persons living, working or congregating in Flood Hazard While the site is subject to flood hazard designations, the proposed
to and including a 1% AEP (1:100 year ARI) Areas identified on Overlay Maps OM1.3—OM9.3; or development is not within a flood hazard area.
flood event.
S14.2 At least one access route above the 1% AEP (1:100 year Refer to Appendix E – Engineering Report.
ARI) flood level is available for evacuation; or
S14.3 An area of sufficient size and dimensions to accommodate
users is provided, above the 1% AEP (1:100 year ARI) flood
level that allows for safe congregation and evacuation;
AND
S14.4 Works avoid any reductions in on-site flood storage capacity
and contain within the site any adverse changes, including
December 2014 Cardno HRP A53