Skip to the record
Accept no imitations.

Original source · versioned page text

MCU14/0106 & OPW15/0001 Town Planning Report & Appendix A Code Compliance

of 239

Page text shows just the words. Original shows the document exactly as it was published.

Original PDF page 138, section 1. The text section number identifies this passage in the reader.

                                                                                                                                                                                    Town Planning Report
                                                                                                     28 Eenie Creek Road, Noosaville and parts of the road reserves of Hofmann Drive and Walter Hay Drive



A6 – Community Uses Code
Table 14-17 – For all Community Uses
 Specific Outcome                                           Probable Solution                                                            Response
 14.31 Effects of use
 Electricity supply infrastructure
 O1       The development does not adversely impact        S1.1     No solution provided                                                 R1.1 Alternative Solution (as no Probable Solution is provided)
          on existing or future electricity supply                                                                                       The proposed development does not adversely impact on existing or
          infrastructure;                                                                                                                future electricity supply infrastructure
          AND                                                                                                                            Refer to Appendix E – Engineering Report.
 O2       All uses and works maintain an adequate          S2.1     Development for uses adjacent to or within 50m of an existing        R2.1 Not Applicable
          safe distance from electrical infrastructure              electricity substation incorporates noise attenuation measures       The proposed development is not located adjacent to or within 50m of
          including substations, overhead powerlines,               to mitigate noise impacts;                                           an existing electricity substation.
          power poles and transformers.                             AND
                                                           S2.2     Buildings and structures (including swimming pools, sheds,           R2.2 Complies
                                                                    tennis courts and outbuildings) are not constructed under            The proposed development is not constructed under overhead
                                                                    overhead electricity transmission lines, or within electricity       electricity transmission lines, or within electricity easements.
                                                                    easements;
                                                                    AND
                                                           S2.3     A minimum separation distance is maintained from the                 R2.3 Complies
                                                                    electricity transmission line to the closest boundary of habitable   The proposed development is not located within the minimum
                                                                    buildings and child activity areas, as follows—                      distances specified in S2.3.
                                                                    a)      20m for transmission lines up to 132kV;
                                                                    b)      30m for transmission lines between 133kV and
                                                                            275kV; and
                                                                    c)      40m for transmission lines greater than 275kV.
 Road network function


 O3       The use does not have an adverse impact on                No solution provided                                                 R3 Alternative Solution (as no Probable Solution is provided)
          the safety and efficiency of the road network;                                                                                 The proposed development does not adversely impact on the safety
          AND                                                                                                                            and efficiency of the road network.
                                                                                                                                         Refer to Appendix D – Traffic Impact Assessment for further
                                                                                                                                         details.
 O4       The surrounding road system is capable of                 No solution provided                                                 R4 Alternative Solution (as no Probable Solution is provided)
          accommodating additional traffic generated                                                                                     The surrounding road system is capable of accommodating additional
          by the proposal.                                                                                                               traffic generated by the proposal.
                                                                                                                                         Refer to Appendix D – Traffic Impact Assessment for further
                                                                                                                                         details.




December 2014                                                                              Cardno HRP                                                                                             A57
Log in to download the original file

MCU14_0106 & OPW15_0001 Town Planning Report & Appendix A Code Compliance.pdf · 3.7 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.