Original source · versioned page text
MCU14/0106 & OPW15/0001 Town Planning Report & Appendix A Code Compliance
Original PDF page 183, section 1. The text section number identifies this passage in the reader.
Town Planning Report
28 Eenie Creek Road, Noosaville and parts of the road reserves of Hofmann Drive and Walter Hay Drive
Specific Outcome Probable Solution Response
Water management for waste storage areas
O7 Waste storage areas are designed to contain S7.1 The waste storage area — R7.1 Will Comply
and appropriately dispose of leakage from a) is bunded and graded so that washwater and bin leakage Management and design measures will ensure that the
bins and wastewater from bin washing. are drained to the sewer or an on-site effluent disposal environmental values of any downstream receiving waters are
system via a gully within the storage area; protected.
b) has a bund wall with a maximum height of 100mm;
c) is serviced by a conveniently located hosecock and
backflow prevention device, and connected to a water
supply; and
d) is roofed or otherwise covered if the storage area is—
i) more than 1m2; or
ii) storing wet waste; or
iii) storing other waste with a high potential to cause
pollution if washed or leaked from the bins, including waste
oil or putrescibles.
December 2014 Cardno HRP A102
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.