MCU14/0106 & OPW15/0001 Town Planning Report & Appendix A Code Compliance

of 239

Page text shows just the words. Original shows the document exactly as it was published.

Original PDF page 190, section 1. The text section number identifies this passage in the reader.

                                                                                                                                                                                         Town Planning Report
                                                                                                          28 Eenie Creek Road, Noosaville and parts of the road reserves of Hofmann Drive and Walter Hay Drive



 Performance Outcomes                                       Acceptable Outcomes                                                             Response
                                                            AO2.3 Development within a coastal hazard area is located, designed and         R2.3 Not Applicable
                                                            constructed to ensure exposed structures can sustain flooding from a
                                                            defined storm tide event.
                                                            AND
                                                            AO2.4 Essential community service infrastructure is:                            R2.4 Not Applicable
                                                            (1) located so that it is not inundated by a recommended storm tide event       Not essential community service infrastructure.
                                                                  specified for that infrastructure, or
                                                            (2) located and designed to ensure any components of the infrastructure
                                                                  that are likely to fail to function or may result in contamination when
                                                                  inundated by a storm tide (for example, electrical switch gear and
                                                                  motors, water supply pipeline air valves) are:
                                                                   (a)   located above the peak water level for a recommended storm
                                                                         tide event, or
                                                                   (b)   designed and constructed to exclude storm tide intrusions or
                                                                         infiltration (including by being located in the ground), or
                                                                   (c)   able to temporarily stop functioning during a recommended
                                                                         storm tide event without causing significant adverse impacts to
                                                                         the infrastructure or the community.
                                                            AND
                                                            AO2.5 Emergency services infrastructure and emergency shelters, police          R2.5 Not Applicable
                                                            facilities, and hospitals and associated facilities have an emergency rescue
                                                            area above the peak water level for a recommended storm tide event.
 PO3 Development directly, indirectly and cumulatively      AO3.1 Development avoids increasing the number of premises from which           R3.1 Complies
 avoids an unacceptable increase in the severity of the     people would need to be evacuated to prevent death or injury from a             The development is outside the influence of storm tide
 coastal hazard, and does not significantly increase the    defined storm tide event.
 potential for damage on the premises or to other
 premises.
 PO4 Development avoids the release of hazardous            AO4.1 Development that involves the manufacture or storage of                   R4.1 Not Applicable
 materials as a result of a natural hazard event.           hazardous materials in bulk are designed to:                                    No hazardous material proposed to be manufactured or stored on
 Editor’s note: Applications should:                        (1) prevent the intrusion of waters from a defined storm tide event into        site
 (1)   assess the risk of storm tide inundation releasing         structures or facilities containing the hazardous materials, or
       or otherwise exposing hazardous materials,           (2) ensure hazardous materials remain secured despite inundation,
       including appropriate emergency planning and               including secure from the effects of hydrodynamic forcing associated
       contingency measures.                                      with wave action or flowing water.
 (2)   applications are to be supported by a report
       certified by a Registered Professional Engineer
       of Queensland (RPEQ) that demonstrates this
       performance outcome will be achieved.
                                                            AO5.1 Development in an erosion prone area within the coastal                   R5 Not Applicable
                                                            management district:




December 2014                                                                                    Cardno HRP                                                                                          A109
Log in to download the original file

MCU14_0106 & OPW15_0001 Town Planning Report & Appendix A Code Compliance.pdf · 3.7 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.