Stormwater Treatment & Water Quality Management Plan_April2014

Attached to the e-mail REC13/0146 - Response to Information Request - Email 2.

of 90

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
maintenance                                                                                          necessary) following first
                     Remove accumulated sediments at inlet
                                                                                                     year.
                     Remove impermeable layer (such as oily or clayey sediment)
                      if water ponds for more than a few hours
                     Remove weeds and dead plants
                     Replace plants where necessary (8-10 plants per m2 is
                      required). Ensure even spacing of plants.
                     Water plants as necessary
                     Check if a small clear flow is discharging from seepage pipe
                      to overflow pit after soaking rain. Repair blockages in pipes if
                      necessary
                     Treat plants for disease, pests etc.
                     Water plants as necessary
                     Reinstate areas that have eroded and holes in media
                     Ensure energy dissipation at entry and exit points is adequate
                      and repair if necessary
                     Ensure builder is aware that when working upstream they are
                      to block inlet to biopod with filter bags and ring edge with
                      sediment fence.
Every ten years      Remove the top 50mm of filter material                               Council   Every ten years (or as
                                                                                                     necessary)
                     If after the removal of the top 50mm of filter material the water
                      ponds for more than 2 hours after inflow stops. Test hydraulic
                      conductivity of filter media (Replace filter media if conductivity
                      is below the minimum of 50 mm/hr).
Inspections          Carry out three monthly inspections of the system and inspect        Council   Every six months –or as
                      the following:                                                                 necessary.
                         o   Sediment build up on surface
                         o   Impermeable layer (such as oily or clayey sediment)
                             build up
Log in to download the original file

Stormwater Treatment & Water Quality Management Plan_April2014.pdf · 5.3 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.