Council archive · source document
20150426 - Engineering Drawings · 132007.2062
Attached to the e-mail OPW16/0050 - Operational Works Application 1 of 2.
GENERAL NOTES e THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL AND OTHER CONSULTANTS DRAWINGS AND SPECIFICATIONS AND WITH SUCH OTHER WRITTEN INSTRUCTIONS AS MAY BE ISSUED DURING THE COURSE OF THE CONTRACT. ALL DISCREPANCIES SHALL BE REFERRED TO THE SUPERINTENDENT FOR DECISION BEFORE PROCEEDING WITH THE WORK. e ALL DIMENSIONS RELEVANT TO SETTING OUT AND OFF-SITE WORK SHALL BE VERIFIED BY THE CONTRACTOR BEFORE CONSTRUCTION AND FABRICATION IS COMMENCED, THE ENGINEER'S DRAWINGS SHALL NOT BE SCALED. « DURING CONSTRUCTION THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE STRUCTURE IN A STABLE CONDITION AND ENSURE NO PART IS OVER-STRESSED. « WHERE EXCAVATION WORK IS TO BE CARRIED OUT ADJACENT TO EXISTING FOOTINGS, THE EXACT LEVEL OF THE UNDERSIDE OF THE FOOTINGS SHALL BE OBTAINED BY TEST PITS PRIOR TO EXCAVATION. UNDERPINNING AND SHORING OF THE STRUCTURE SHALL BE CARRIED OUT AS REQUIRED AND THE EXISTING STRUCTURE SHALL BE MAINTAINED IN A STABLE AND UNDAMAGED CONDITION, « WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH THE RELEVANT CURRENT SAA CODES (INCLUDING ALL AMENDMENTS) AND THE STATUTORY AUTHORITIES REQUIREMENTS, EXCEPT WHERE VARIED BY THE CONTRACT DOCUMENTS. e ALL DIMENSIONS ARE IN MILLIMETRES, UNLESS NOTES OTHERWISE, ALL LEVELS ARE EXPRESSED IN METRES. FOOTING NOTES e ALL FOOTING EXCAVATIONS SHALL BE CLEANED OF LOOSE MATERIALS AND WATER, e WHERE VERIFIED FOUNDATION MATERIAL IS BELOW THE UNDERSIDE OF FOOTINGS AS DETAILED, BACKFILL ADDITIONAL EXCAVATION WITH WEAK MIX CONCRETE. « SIDES OF FOOTINGS SHALL BE FORMED AS NECESSARY WHEN EXCAVATED FACE |S NOT STABLE. e¢ ALL WALLS AND COLUMNS SHALL BE CONCENTRIC WITH SUPPORTING FOOTINGS, UNLESS OTHERWISE NOTED ON THE DRAWINGS, e UNLESS APPROVED BY THE SUPERINTENDENT, EXCAVATIONS SHALL NOT EXTEND BELOW A LINE DIPPING AT 30° AND AWAY FROM THE NEAREST UNDERSIDE CORNER OF ANY FOOTINGS. BLOCKWORK NOTES ¢ BLOCKWORK SHALL NOT BE FILLED TO A HEIGHT OF GREATER THAN 2400mm, DURING ANY ONE POUR. * CONCRETE BLOCKS TO HAVE A CHARACTERISTIC STRENGTH OF IS5MPa MINIMUM. ¢ BUILD ALL FIXINGS FOR ARCHITECTURAL DETAILS, * ALL BLOCKWORK MATERIALS AND WORKMANSHIP SHALL COMPLY WITH AS3700. BLOCKS FOR USE IN REINFORCED CONCRETE FILLED WALLS SHALL BE 20.48 ¢ 15.48 SERIES. * MORTAR SHALL BE MIXED BY MECHANICAL MIXERS IN ACCORDANCE WITH ASI23 IN THE FOLLOWING PROPORTIONS BY VOLUME OF- PORTLAND CEMENT : HYDRATED LIME : CLEAN PIT SAND, - BELOW DAMP COURSE LEVEL | : 0.25 : 3 - ABOVE DAMP COURSE LEVEL | : |: 6 ALL BLOCKS SHALL BE LAID ON A FULL BED OF MORTAR. e ALL WALLS SHALL BE BONDED OR TIED AT THEIR INTERSECTIONS, * REINFORCED CONCRETE MASONRY WALLS SHALL BE FILLED WITH GROUT OF F'c = 20MPa; SLUMP = 225mm; MAXIMUM AGGREGATE SIZE = 5mm; CLEAN OUT BLOCKS SHALL BE EMPLOYED IN THE BOTTOM COURSE AND ALL MORTAR DROPPINGS RAKED OUT PRIOR TO FILLING. ¢ GROUT FILLING SHALL BE THOROUGHLY RODDED USING A PLAIN ROUND BAR, TIMBER NOTES e ALL TIMBER ELEMENTS AND CONSTRUCTION DETAIL ARE TO COMPLY WITH THE DETAILS GIVEN IN AS51684 NATIONAL TIMBER FRAMING CODE WIND CLASSIFICATION N3. « ALL TRUSSES TO BE DESIGNED BY THE MANUFACTURER TO THE WIND LOAD SPECIFIED, THE TRUSS MANUFACTURER IS TO SPECIFY THE TIEDOWN TO TOP PLATE APPROPRIATE TO THE SPECIFIED DESIGN WIND VELOCITY. e ALL TIE DOWN DETAILS TO BE SUBMITTED TO THE SUPERINTENDENT FOR VERIFICATION. R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model, 26/11/2015 9:25:07 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100 STRUCTURAL STEELWORK NOTES « ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS4I00, AS/NZS4600, AS/NZS1554 AND AS/NZSHB62. « UNLESS NOTED OTHERWISE, ALL STEEL SHALL BE: - GRADE 300 PLUS FOR HOT ROLLED SECTIONS, - GRADE 300 PLUS FOR WELDED SECTIONS (WB, WC). - GRADE 300 PLUS FOR MERCHANT BAR (ROUND, SQUARE AND FLAT). - GRADE 250 FOR PLATES, - GRADE C350 FOR RHS, SHS AND CHS, * COMMERCIAL GRADE BOLTS SHALL CONFORM TO AS/NZSIII! AND AS4I00, HIGH STRENGTH STRUCTURAL BOLTS SHALL CONFORM TO AS/NZSI252 AND AS4I00. WELDS SHALL CONFORM TO AS/NZSI554 AND WELDING ELECTRODES TO AS/NZSI553, « ALL DETAILS, GAUGE LINES, ETC, WHERE NOT SPECIFICALLY SHOWN ARE TO BE IN ACCORDANCE WITH AISC DESIGN CAPACITY TABLES FOR STRUCTURAL STEEL AND AISC STANDARDISED STRUCTURAL CONNECTIONS. ¢ BEFORE FABRICATION IS COMMENCED THE CONTRACTOR SHALL SUBMIT COPIES OF THE SHOP DRAWINGS TO RIENMAC FOR REVIEW. REVIEW DOES NOT INCLUDE CHECKING OF DIMENSIONS, e UNLESS NOTED OTHERWISE, ALL WELDS SHALL BE 6mm CONTINUOUS FILLET FROM E48XX ELECTRODES. ALL WELDS SHALL BE CATEGORY SP. e ALL BOLTS SHALL BE GRADE 8.8/5 UNLESS NOTED OTHERNISE. ALL BOLTS SHALL BE M20, UNLESS NOTED OTHERNISE, * ALL CLEATS AND GUSSETS SHALL BE l0mm PLATE, UNLESS NOTED OTHERWISE. « CONCRETE ENCASED STEELWORK SHALL HAVE A MINIMUM OF 50mm OF CONCRETE ENCASEMENT REINFORCED WITH W5 WIRE WRAPPING AT [50 CRS OR FGW4l FABRIC, UNLESS NOTED OTHERNISE. ¢ STRUCTURAL STEELWORK SHALL HAVE THE FOLLOWING SURFACE TREATMENT IN ACCORDANCE WITH AS/NZS23I2, UNLESS NOTED OTHERWISE, ELEMENT SURFACE CLEANING PRIME COAT TOP COATS ALL STEELWORK 75 MICRONS REFER ARCHITECT WITHIN AIRSEAL CLASS | ZINCPHOSPHATE OF BUILDING ALL STEELWORK HOT DIP REFER ARCHITECT OUTSIDE AIRSEAL CLASS 2.5 GALVANISED OF BUILDING *« MEMBERS TO BE ENCASED IN CONCRETE OR FIRE SPRAYED MUST NOT BE PAINTED, « ALL HOT DIP GALVANISED MEMBERS SHALL BE PROVIDED WITH VENT AND DRAINAGE HOLES IN ACCORDANCE WITH THE GALVANISER'S RECOMMENDATIONS, ¢ WHERE MEMBERS SHOWN ON THE STRUCTURAL OR ARCHITECTURAL DRAWINGS ARE REQUIRED TO BE CURVED, BENT OR ROLLED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE METHODS. REQUIRED TO ACHIEVE THE REQUIRED SHAPES WITHOUT LOCALISED DISTORTION OF THE MEMBERS. ¢ TRIMMING MEMBERS FOR MECHANICAL/HYDRAULIC PENETRATIONS ARE NOT NECESSARILY SHOWN. ¢ TRIMMING MEMBERS FOR VALLEYS, FREE EDGES, RIDGES, ETC ARE NOT NECESSARILY SHOWN, REFER TO PURLIN MANUFACTURER'S FOR DETAILS. ¢ F.S.B.W. INDICATES COMPLETE PENETRATION FULL STRENGTH BUTT WELD. ¢ THE CONTRACTOR SHALL PROVIDE AND LEAVE IN PLACE UNTIL PERMANENT BRACING ELEMENTS ARE CONSTRUCTED, SUCH TEMPORARY BRACING AS IS NECESSARY TO STABILISE THE STRUCTURE DURING ERECTION. * ROOF AND/OR WALL SHEETING SHALL BE FIXED TO PURLINS OR GIRTS IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ¢ CAP HOLLOW SECTIONS WITH 3mm END PLATES, UNO. * FOR GALVANISED COATINGS, REPAIR DAMAGE AND SITE WELDS WITH TWO COATS OF TWO PACK EPOXY POLYAMIDE ZINC-RICH PAINT CONTAINING A MINIMUM 92% ZINC DUST IN THE DRY FILM, *« GROUT UNDER BASEPLATES TO BE HIGH STRENGTH CEMENTITIOUS, NON-SHRINK MASTERFLOW 870 or EQUIVALENT, UNO. RIENMAC ery ito ABN. 52 010 666 430 AC.N. 010 666 430 CONSULTING CIVIL & STRUCTURAL ENGINEERS SUNSHINE COAST OFFICE: SUITE 5, FIRST FLOOR, SAINT CIRINO, F [37 BRISBANE ROAD, Email (PO BOx 144) MOOLOOLABA @LD 4557 P:- (07) 5478 250d (07) 5444 |I5q [email protected] [email protected]! Web:- www.rienmac. bi: CLIENT: CONNETIVITY PTY LTD PROJECT: PROPOSED UNITS LOT 219 CORSAIR CRESENT SUNRISE BEACH @LD 4567 REAL PROPERTY DESCRIPTION # COUNCIL: LOT 219, RP 135364 PARISH OF WEYBA, COUNTY OF MARCH SUNSHINE COAST REGIONAL COUNCIL DRAWING TITLE: GENERAL NOTES Designed: PLR Drawn: LR SCALES: Engineer: PLR DATE: 25 MAY I5 5330 | SIla A rine hae Band iy Cees wt | JOB NUMBER DWG No. | ISSUE PETER RIENECKER - RPEQ@ 2088 DO NOT SCALE OFF DRAWINGS, | A3 |SHEET 18 OF 21 |CHECKED: PLR
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20150426 - Engineering Drawings.pdfRelated documentApplication case desk ↗
20150426 - Engineering Drawings.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.