20150426 - Engineering Drawings · 132007.2062
Attached to the e-mail OPW16/0050 - Operational Works Application 1 of 2.
CONCRETE NOTES ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS3600. ALL SLABS ON GROUND TO BE CAST ON A WATERPROOF MEMBRANE ON A 50mm SAND BED. MEMBRANE IS TO EXTEND UNDER INTEGRAL GROUND BEAMS AND |S TO BE EXTENDED A MINIMUM OF 200mm DOWN THE FACE OF DEEP BEAMS, MEMBRANE IS TO BE POLYETHYLENE FILM 0.2mm THICK AND IMPACT RESISTANT. LAP JOINTS 200mm AND SEAL THE LAPS WITH WATERPROOF ADHESIVE TAPE, SEAL PENETRATIONS WITH WATERPROOF TAPE, PROVIDE A TERMITE BARRIER IN ACCORDANCE WITH AS3660.1. ALL CONCRETE TO BE VIBRATED. CONCRETE QUALITY SHALL BE NORMAL CLASS, UNLESS NOTED OTHERNISE. MAXIMUM AGGREGATE SIZE = 20mm. SLUMP = 80mm +/- |5mm. CONCRETE STRENGTHS FOR PARTICULAR ELEMENTS SHALL BE AS FOLLOWS, UNLESS NOTED OTHERNISE. ELEMENT CONCRETE STRENGTH FOOTINGS N25 SLABS ON GROUND N25 SUSPENDED SLABS NOT EXPOSED TO WEATHER N32 SUSPENDED SLABS EXPOSED TO WEATHER N40 COLUMNS N40 ELEMENT FORMED- THE CONTRACTOR IS TO NOTIFY THE SUPERINTENDENT IN WRITING OF ANY ADMIXTURES TO BE USED IN THE CONCRETE MIX. NO ADMIXTURES TO BE USED WITHOUT APPROVAL OF THE SUPERINTENDENT. CALCIUM CHLORIDE WILL NOT BE PERMITTED AND SHALL NOT BE USED UNDER ANY CIRCUMSTANCES, CONCRETE TESTING - ALL TESTING SHALL BE BY 'PROJECT ASSESSMENT' AS PER AS3600. ALL FORMWORK TO BE DESIGNED, CONSTRUCTED AND REMOVED IN ACCORDANCE WITH AS53610. CLASS OF FORMWORK TO BE IN ACCORDANCE WITH AS53610, TABLE 3.3.1, UNLESS SPECIFICALLY STATED OTHERWISE, ALL EXTERNAL CORNERS OF CONCRETE SHALL BE CHAMFERED BY THE INCLUSION OF FILLETS IN THE FORMWORK. THE FILLETS SHALL HAVE A 20mm FACE TO THE CONCRETE, FINISHED TO THE SAME STANDARD AS THE FORMWORK AND SHALL BE MITRED AT CORNERS. ALL EXPOSED FORMED SURFACES SHALL HAVE CLASS 2 SURFACE FINISH TO AS36I0 AND ALL UNSEEN AREAS SHALL HAVE CLASS 4 SURFACE FINISH TO AS36I0. DIMENSIONAL TOLERANCE OF FORMWORK FOR CLASS 2 TO BE MAXIMUM I5mm DEVIATION FROM CORRECT POSITION, CLASS 3 - 20mm AND CLASS 4 - 25mm. POSITIONAL TOLERANCE OF FORMWORK FOR CLASS 2 TO BE MAXIMUM 5mm DEVIATION FROM CORRECT POSITION, CLASS 3 - 20mm AND CLASS 4 - 25mm. MINIMUM COVER TO ALL REINFORCEMENT, UNLESS NOTED OTHERWISE SHALL BE AS FOLLOWS:- FORMED- NOT FORMED- NOT EXPOSED EXPOSED TO CAST AGAINST TO WEATHER GROUND, WATER GROUND, ETC. OR WEATHER COLUMN 50 50 60 BEAM 40 40 60 FOOTINGS -- 50 60 SLAB 30 40 60 WALL 25 40 60 R:\rienmacfiles\Rienmac\15\Large\15330 - Lt 219 Corsair Cr, Sunrise Bch - Steve-Dianne Selby - Des Crawford\15330.dwg, Model, 26/11/2015 9:25:21 AM, L Roth, Rienmac Pty Ltd, CutePDF Writer, A3, 1:100 CONCRETE NOTES CONT NO HOLES GREATER THAN 150mm, CHASES OR EMBEDMENT OF PIPES GREATER THAN 40mm OTHER THAN THOSE SHOWN OF THE STRUCTURAL DRAWINGS SHALL BE MADE IN THE CONCRETE SLABS WITHOUT PRIOR APPROVAL OF THE SUPERINTENDENT. FOR ALL OTHER CONCRETE MEMBERS NO PENETRATION, CHASES OR EMBEDMENT SHALL BE MADE WITHOUT PRIOR APPROVAL OF THE SUPERINTENDENT, CONDUITS CAST INTO CONCRETE MEMBERS SHALL BE SPACED AT MAXIMUM DISTANCE POSSIBLE AND UNDER NO CIRCUMSTANCES CLOSER THAN A CLEAR SPACE SPACING OF TWICE THE LARGER CONDUIT DIAMETER FROM PARALLEL REINFORCEMENT OR ANY OTHER CONDUIT. ALL REINFORCEMENT SHALL BE SECURELY SUPPORTED IN ITS CORRECT POSITION DURING CONCRETING BY APPROVED PLASTIC TIPPED BAR CHAIRS, MAXIMUM CENTRES OF SUPPORTING CHAIRS SHALL BE 600mm FOR FABRIC, 600mm FOR BARS UP TO 12mm, %00mm FOR BARS lémm AND GREATER. CONSTRUCTION BREAK LOCATION AND DETAILS SHALL BE APPROVED BY THE SUPERINTENDENT PRIOR TO COMMENCEMENT, THE FACE OF ALL CONCRETE AGAINST WHICH NEW CONCRETE IS TO BE CAST IS TO BE THOROUGHLY MECHANICALLY SCABBLED, FULLY EXPOSING THE AGGREGATE MATRIX. ALL CONCRETE SURFACES ARE TO CURED FOR SEVEN DAYS AFTER CASTING USING A METHOD APPROVED BY THE SUPERINTENDENT. FIRST SLAB BAR IS TO BE POSITIONED MAXIMUM |00mm FROM FACE OF BEAMS, R.C. WALLS AND SLAB THICKENING PARALLEL TO BAR, EXACT SIZE AND LOCATION OF PENETRATIONS ARE TO BE OBTAINED FROM WORKSHOP DRAWINGS PRIOR TO SCHEDULING OF REINFORCEMENT, AND ARE NOT TO EXCEED DIMENSIONS WHERE SHOWN ON STRUCTURAL DRAWINGS, REINFORCEMENT IS SHOWN DIAGRAMMATICALLY AND NOT NECESSARILY IN TRUE PROJECTION, UNDER NO CIRCUMSTANCES IS REINFORCEMENT TO BE CUT ON SITE TO CLEAR PENETRATION WITHOUT APPROVAL BY THE SUPERINTENDENT, DISPLACE REINFORCEMENT SLIGHTLY AS NECESSARY TO CLEAR BLOCKOUTS. SPLICES IN REINFORCEMENT SHALL BE MADE ONLY IN THE POSITIONS SHOWN OR AS OTHERWISE APPROVED BY THE SUPERINTENDENT. WELDING OF REINFORCEMENT SHALL NOT BE PERMITTED WITHOUT APPROVAL BY THE SUPERINTENDENT. REINFORCEMENT SHALL BE BENT COLD IN ACCORDANCE WITH AS3600 EXCEPT WHERE APPROVAL BY THE SUPERINTENDENT. NO REBENDING SHALL BE PERMITTED UNLESS APPROVED BY THE SUPERINTENDENT. RIENMAC ery ito ABN. 52 010 666 430 AC.N. 010 666 430 CONSULTING CIVIL & STRUCTURAL ENGINEERS SUNSHINE COAST OFFICE: SUITE 5, FIRST FLOOR, SAINT CIRINO, F [37 BRISBANE ROAD, Email (PO BOx 144) MOOLOOLABA @LD 4557 P:- (07) 5478 250d (07) 5444 |I5q [email protected] [email protected]! Web:- www.rienmac. bi: CLIENT: CONNETIVITY PTY LTD PROJECT: PROPOSED UNITS LOT 219 CORSAIR CRESENT SUNRISE BEACH @LD 4567 REAL PROPERTY DESCRIPTION # COUNCIL: LOT 219, RP 135364 PARISH OF WEYBA, COUNTY OF MARCH SUNSHINE COAST REGIONAL COUNCIL DRAWING TITLE: CONCRETE NOTES Designed: PLR Drawn: LR SCALES: Engineer: PLR |DATE: 25 MAY I5 5330 | 519 A rin he Band iy Cees tm wt | JOB NUMBER DWG No. | ISSUE PETER RIENECKER - RPEQ@ 2088 DO NOT SCALE OFF DRAWINGS, | A3 |SHEET !4 OF 2i |CHECKED: PLR
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20150426 - Engineering Drawings.pdfRelated documentApplication case desk ↗
20150426 - Engineering Drawings.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.