Performance Total suspended solids 45%
Claims (ER) Total phosphorus 47%
Total nitrogen 25%
Total petroleum Not claimed
hydrocarbons
Gross pollutants 100 %
IEP’s comments: Nil.
IEP’s recommendations: All performance claims are considered compliant up to the
treatment flow rate for the applicable device. Verified flow rates are included in the table
below:
Size of Stormsack (Pit TFR for MUSIC modelling – high
dimensions) (mm) flow bypass in litres per second
450 x 450 10
600 x 600 25
600 x 900 32
900 x 900 39
1200 x 900 50
1200 x 1200 65
Test Stormwater 21 compliant stormwater events. Water chemistry was compliant with Table 1 in
Runoff SQIDEP v1.3. Minimum number of aliquots collected, and samples were
representative.
Test Catchment - The field testing for the ATLAN Stormsack (200) was carried out at Griffith University,
Carpark H, Parkland Campus, Griffith Way, Southport, QLD, 4215.
- The catchment area draining to the device was reported to be 1,181 m2 directly connected
to the Stormsack. The catchment was reported to be 66% impervious with the remainder
including a eucalyptus forested area which drains to the Stormsack.
Maintenance The Stormsack should be cleaned/maintained when accumulated pollutants reach
Performed during the trigger level of 150mm depth in the bag, or 50% capacity by volume.
monitoring
The monitored Stormsack was maintained twice during the SQIDEP monitoring
program due to construction loads received from earthworks undertaken in the
upstream catchment. Regular inspection of the Stormsack is recommended, as per
the manufacturer’s O&M manual.