Original source · versioned page text
20230025_RECOR_MCU Engineers Letter_20.12.24
Verified method:
The Reviewers have verified that the method undertaken complies with the intent and specifics of
SQIDEP v1.3.
A more detailed Independent Evaluatores Report is available to get an understanding of what was
checked and how the claim was verified.
Conditions/Notes
MUSIC modelling shall be carried out as follows:
A generic node is to be used in MUSIC with a high flow bypass set to the applicable TFR (see
table below) for the size of the Atlan Stormsack proposed and with inlet and outlet
concentrations as follows:
Pollutant Inlet concentration Outlet Concentration
TSS 100 55
TP 100 53
TN 10 7.5
Size of Stormsack (Pit dimensions) TFR for MUSIC modelling – high flow
(mm) bypass in litres per second
450 x 450 10
600 x 600 25
600 x 900 32
900 x 900 39
1200 x 900 50
1200 x 1200 65