Acceptable Outcomes
Performance Outcomes
Plot ratio of development: For a dwelling house, plot ration of
development does not exceed 0.4:1
1. does not exceed 0.4:1; or
2. for small dwellings or for development
which provides a ratio of at least three
small dwellings to one other dwelling,
does not exceed 0.5:1.
Building Setback NA – all work under existing roofline
PO12 AO12.1
Buildings and structures are designed and sited Buildings and structures meet the following
to: minimum boundary setbacks:
1. provide a high level of amenity to users of 1. for frontages — 6 metres
the subject site and adjoining premises, 2. for side boundaries—
including provision of visual and acoustic
privacy; 1. 1.5 metres setback up to 4.5
2. not unreasonably obstruct views or cause metres height;
overlooking of private open space or 2. 2 metres setback between 4.5
habitable areas of adjoining premises; metres and 7.5 metres height;
3. provide adequate distance from adjoining and
land uses; 3. 2.5 metres where above 7.5
4. preserve existing vegetation that will help metres height
buffer development; 3. for the rear boundary - 6 metres
5. allow for space and landscaping to be
provided between buildings including AO12.2
adequate area at ground level for The front 6 metres of the property is
landscaping with trees, shrubs, outdoor landscaped open space, provided that
living and utilities; uncovered visitor parking, or swimming
6. be consistent with the predominant pools protruding no more than 1 metre above
character of the surrounding area; and the ground level, can be as close as 2 metres
7. protect the natural character and avoid from the front boundary.
adverse impacts on ecologically important
areas such as national parks, waterways AO12.3
and wetlands. Relocatable homes are set back not less than:
(a) 6 metres from a road frontage;
(b) 1.5 metres from any other site boundary;
and
(c) 3 metres from an internal road
AO12.4
Buildings and structures on premises with
frontage to the Noosa River system are set back
not less than 10 metres from mean high water
spring as shown in Figure AP3-15A.
Alternative provision to the QDC
Setback to a watercourse in the Noosa Waters AO13 NA – all work under existing roofline
estate, Noosaville For premises adjoining a watercourse within the
PO13 Noosa Waters estate no building work, filling or
Land adjoining the revetment wall and for a excavation works occurs within 4.5 metres from
width of 4.5 metres serves flood detention and the centre line of the top of the concrete
amenity functions, free of structures and revetment wall.
impervious surfaces.
Editor's note refer to figure 6.3.1.5
Alternative provision to the QDC