32.   Unobstructed access shall be provided to the Lower Ground Level at all times. Should a
      security gate or similar barrier be constructed to prevent unauthorised access to the Lower
      Ground Level the property owner shall install an intercom system. The intercom system shall
      be sufficient to permit entrance to the basement by visitors of all of the units.
33.   A small sign shall be installed within the site (in a clearly visible location for all vehicles to see
      near the entry to the car parking area) to advise visitors that visitor car parking spaces are
      provided within the basement car park and to use the intercom system (if applicable) to
      contact the unit manager or the unit occupier they are visiting to enable entry to the basement
      and to these spaces.
34.   The Ground Level car parking area alignment shall be revised to be perpendicular to the
      access driveway. The revised layout shall provide sufficient manoeuvring area within the
      carspaces and access driveway to permit vehicles to access the spaces, manoeuvre and
      leave the site in a forward gear in a total of 3 movements.
35.   A minimum of 3 uncovered car park spaces and 41 covered car park spaces shall be provided
      on site, including 2 clearly defined disabled car park spaces.
36.   The car parking area shall be designed to comply with the provisions of AS/NZS 2890.1-2004
      for user class 1A with allowance for vehicles to enter and leave the site in a forward gear and
      with a minimum head clearance (headroom) at any point of 2.3m.
37.   The proposed turning area at the end of the aisle that serves proposed car park spaces 8 to
      14 shall be line-marked with chevrons and have the words “No Parking” painted on the
      pavement. A sign shall also be provided to indicate that the area is a “Turning Area Only” and
      that “No Parking is Permitted”.
38.   All car parking shall be kept, maintained and line-marked in a condition fit for use.
Frontage Works
39.   Footpath improvements such as topsoiling, grassing, and tree planting are required to the
      Serenity Close frontage of the site in accordance with Planning Scheme Policy PSP03
      Landscaping Plants & Guidelines. Grass shall be couch, free of weeds.
40.   All redundant vehicular crossings to the site shall be removed and replaced by kerb and
      channel, footpath paving and landscaping such as trees and grasses in accordance with
      Council’s Standard specifications prior to commencement of the use permitted by this permit.
Roof Water & Stormwater Drainage
41.   A stormwater management plan shall be prepared by a RPEQ, specialising in stormwater and
      water quality management incorporating the principles of the Environmental Management Plan
      for the Settlers Cove Development (23118 DA), that demonstrates water reuse strategies,
      infrastructure capacity and effective treatment methodology. The use of rainwater harvesting
      tanks for irrigation purposes shall be incorporated in the overall design plans. These plans
      shall be submitted to Council for approval prior to obtaining a Development Permit for
      Operational Works.
42.   Roof runoff from any new building should be directed to a rainwater storage system or tank
      (minimum 23,000 litres) that is installed to ensure water from the rainwater storage system or
      tank is used for external uses (such as watering gardens, irrigation, ornamental ponds, water
      features, topping-up swimming pools, outdoor cleaning, etc) and for internal (ground floor) use
      in washing machine cold taps and toilet cisterns. All rainwater tanks are to be designed and
      installed in accordance with the approved Stormwater and Water Quality Management Plan
      and the Queensland Development Code (QDC) current at the time of building approval, and
      shall be part of the plumbing application for approval. The location and capacity of the tanks
      shall be clearly shown on the plans submitted for Building Works/Operational Works approval
      and any overflow shall be directed to the stormwater drainage system.


                                                                                         Page 6 of 25

Used in these records

About this file

File size
579 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Decision Notice [As Published].pdf · 579 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.