Original source · versioned page text
Appendix E - Stormwater Management Plan
Attached to the e-mail Multiple Housing – Type 3 Retirement & Special Needs (10 units) - MCU17/0551.
The original of this document is very large (13.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnBox Culvert or Multiple Pipe Outlets
Sizing of the scour rock protection for box culvert outlets were determined using calculations
specified in Section 10.4.15 of QUDM, 2013. Below indicates rock protection requirements and the
adopted outlet rock protection configuration at each culvert outlet.
Central Bioretention Basin Inflow (1500 Southern Bioretention Basin
Location
x 600) Inflow (2 x 750)
Q (m3/s) 1.67 2.08
Area (m2) 0.9 0.88
Outlet Velocity (m/s) 1.9 2.35
Diameter or Width (m) 1.5 0.75
Cell Height (m) 0.6 ‐
Multiple Cells? NO Yes
Length Ratio D:L 3 3
Width (m) 1.5 2.16
Length (m) 4.5 6.5
d50 (mm) 200 200
Thickness of Rock Protection (mm) 400 400