 16 December 2021




                                                    Figure 3 – Treatment Plan

5.3.3.7 MUSIC Results
The resulting percentage based load reductions at the outlet are shown in Table 4 below together
with the Water Quality Objectives for the receiving waters.


                                                                       Residual
                                                      Sources                     % Reduction   Target %
                                                                        Load


 Total Suspended Solids (kg/yr)                         2350             457         80.5         80

 Total Phosporous (kg/yr)                                4.95           1.44         70.8         60

 Total Nitrogen (kg/yr)                                  36.5           17.4         52.2         45

 Gross Pollutants (kg/yr)                                262            2.37         99.1         90
                                 Table 4 – Percentage Based Load Reduction Results




 Excellence with Economy in Engineering                                                                    13
 l:\paige work\8293\16-12-21 stormwater management plan_issue d.docx
Log in to download the original file

RFI - Appendix G SWMP by MPN Consulting.pdf · 5.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.