Council archive · source document
Approved Plans 51994.1263.01
Plans and drawings: the text below has words only, no drawings.
- 2/11 sunseeker close, noosa NOTES: NOOSA COUNCIL 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN DOMESTIC BUILDING CODE. APPROVED PLAN 2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010 51994.1263.01 5 DEC 2016 RESIDENTIAL TIMBER FRAMING MANUAL. 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12 SUNSEEKER CLOSE 4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM JOINT GROUP J2. 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4. 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF. SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH AS 1684.2 2010 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS. 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES 9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO 2057 RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR HER OWN WORK 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000 main r fencing to re 1850 existing timbe 36.539 existing duplex 35.001 max 1800h block wall to form as side of pool + fencing, to continue to extent of rear boundary stepped in line with slope existing pool by line of patio pools by design DN 5636 block retaining 6200 8600 wall max 1400h 4500 line of extension 4500 stepped grass pavers 17.499 existing jetty location 7.487 proposed timber stairs relaxation required landscaping as required NOOSA RIVER site plan PROPOSED: CLIENT: TONY & HELEN TURNER BUILDER:MICK GARDNER MANDY'S DESIGN & DRAFTING SHEET: 1 of 3 DATE: ISSUE NO: PATIO PH: 0428 641 370 PH: 0414 697 882 PH: 0403 481 474 SCALE: 1:200 DEC 2016 D NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
-
NOTES:
2/11 sunseeker close, noosa NOOSA COUNCIL
APPROVED PLAN
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
RESIDENTIAL TIMBER FRAMING MANUAL.
51994.1263.01 5 DEC 2016 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM
JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH
AS 1684.2 2010
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
MANUFACTURERS SPECIFICATIONS.
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS
AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED
11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN
STANDARDS RELATING TO HIS OR HER OWN WORK
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000
UNIT 1
UNIT 2
4120
stairs to be determined
on site by builder
block retaining,
concrete
DN
slab + tiles over
line of floor over
7998
dine
existing line of patio
3040
01 01
ritek roof over
+ timber post
1270
maximum 1400h block retaining wall
natural slope
(revetment wall)
landscaping
1622 200 6000
boundary line
2800
3941
pool by
pools by design
8007 overall
630 elevation D
4000 1720 1658
elevation A
existing
03 of 03 03 of 03
floor plan
max 1800h block wall to form as
side of pool + fencing,
to continue to extent of rear boundary
stepped in line with slope
PROPOSED: CLIENT: TONY & HELEN TURNER BUILDER:MICK GARDNER MANDY'S DESIGN & DRAFTING SHEET: 2 of 3 DATE: ISSUE NO:
PATIO+ POOL PH: 0428 641 370 PH: 0414 697 882 PH: 0403 481 474 SCALE: 1:100 DEC 2016 D
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
Page 3
-
NOTES:
2/11 sunseeker close, noosa NOOSA COUNCIL
APPROVED PLAN
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
RESIDENTIAL TIMBER FRAMING MANUAL.
51994.1263.01 5 DEC 2016 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM
JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH
AS 1684.2 2010
UPPER FLOOR TOP PLATE 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
UPPER FLOOR JOINERY LINE MANUFACTURERS SPECIFICATIONS.
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
2400
9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS
2100
AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
UPPER FLOOR RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED
11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN
GROUND FLOOR TOP PLATE STANDARDS RELATING TO HIS OR HER OWN WORK
GROUND FLOOR JOINERY LINE 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000
2700
2100
200
GROUND FLOOR
PAD LEVEL
elevation A
proposed ritek roof to timber post beams retaining wall and
ritek specifications pool design to engineers specifications
GROUND FLOOR TOP PLATE
2.00°
GROUND FLOOR JOINERY LINE
existing residence
approx patio
plate height
2700
2350
proposed patio
extension
GROUND FLOOR
existing line
of conc patio
natural ground line
Section 1
line of revetment wall
pool location
200series blockwork +
conc slab over extended patio
natural ground line
elevation D
elevations
PROPOSED: CLIENT: TONY & HELEN TURNER BUILDER:MICK GARDNER MANDY'S DESIGN & DRAFTING SHEET: 3 of 3 DATE: ISSUE NO:
PATIO+ POOL PH: 0428 641 370 PH: 0414 697 882 PH: 0403 481 474 SCALE: 1:100 DEC 2016 D
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
Used in these records
Approved Plans 51994.1263.01.pdfRelated documentApplication case desk ↗
About this file
- File size
- 251 KB (small file)
- File type
No other editions are linked here.