Council archive · source document
Approved Plans 51994.1263.01
Plans and drawings: the text below has words only, no drawings.
-
NOTES:
2/11 sunseeker close, noosa NOOSA COUNCIL
APPROVED PLAN
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
RESIDENTIAL TIMBER FRAMING MANUAL.
51994.1263.01 5 DEC 2016 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM
JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH
AS 1684.2 2010
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
MANUFACTURERS SPECIFICATIONS.
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS
AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED
11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN
STANDARDS RELATING TO HIS OR HER OWN WORK
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000
UNIT 1
UNIT 2
4120
stairs to be determined
on site by builder
block retaining,
concrete
DN
slab + tiles over
line of floor over
7998
dine
existing line of patio
3040
01 01
ritek roof over
+ timber post
1270
maximum 1400h block retaining wall
natural slope
(revetment wall)
landscaping
1622 200 6000
boundary line
2800
3941
pool by
pools by design
8007 overall
630 elevation D
4000 1720 1658
elevation A
existing
03 of 03 03 of 03
floor plan
max 1800h block wall to form as
side of pool + fencing,
to continue to extent of rear boundary
stepped in line with slope
PROPOSED: CLIENT: TONY & HELEN TURNER BUILDER:MICK GARDNER MANDY'S DESIGN & DRAFTING SHEET: 2 of 3 DATE: ISSUE NO:
PATIO+ POOL PH: 0428 641 370 PH: 0414 697 882 PH: 0403 481 474 SCALE: 1:100 DEC 2016 D
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans 51994.1263.01.pdfRelated documentApplication case desk ↗
About this file
- File size
- 251 KB (small file)
- File type
No other editions are linked here.