Approved Plans 51994.1263.01
Plans and drawings: the text below has words only, no drawings.
-
NOTES:
2/11 sunseeker close, noosa NOOSA COUNCIL
APPROVED PLAN
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
RESIDENTIAL TIMBER FRAMING MANUAL.
51994.1263.01 5 DEC 2016 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM
JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH
AS 1684.2 2010
UPPER FLOOR TOP PLATE 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
UPPER FLOOR JOINERY LINE MANUFACTURERS SPECIFICATIONS.
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
2400
9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS
2100
AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
UPPER FLOOR RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED
11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN
GROUND FLOOR TOP PLATE STANDARDS RELATING TO HIS OR HER OWN WORK
GROUND FLOOR JOINERY LINE 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000
2700
2100
200
GROUND FLOOR
PAD LEVEL
elevation A
proposed ritek roof to timber post beams retaining wall and
ritek specifications pool design to engineers specifications
GROUND FLOOR TOP PLATE
2.00°
GROUND FLOOR JOINERY LINE
existing residence
approx patio
plate height
2700
2350
proposed patio
extension
GROUND FLOOR
existing line
of conc patio
natural ground line
Section 1
line of revetment wall
pool location
200series blockwork +
conc slab over extended patio
natural ground line
elevation D
elevations
PROPOSED: CLIENT: TONY & HELEN TURNER BUILDER:MICK GARDNER MANDY'S DESIGN & DRAFTING SHEET: 3 of 3 DATE: ISSUE NO:
PATIO+ POOL PH: 0428 641 370 PH: 0414 697 882 PH: 0403 481 474 SCALE: 1:100 DEC 2016 D
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH