Performance outcomes                                         Acceptable Outcomes
                                                                  above finished floor level;
                                                             (b)    windows and other openings are permanently screened
                                                                    to a minimum height of 1.7 metres to avoid overlooking;
                                                             (c)    windows and doors use translucent glazing to obscure
                                                                    views; or
                                                             (d)    windows or balconies are offset by 45 degrees or more.

                                                             Editor's note—refer to figure AP3­1C

                                                             AO18.5
                                                             Planter boxes, screens, pergolas, landscaping and
                                                             architectural design of balconies are used to screen the
                                                             ground floor private open space of dwellings from separate
                                                             upper­level dwellings.

                                                             AO18.6
                                                             Permanently fixed external screening devices complement the
                                                             building's external materials and finishes and may incorporate
                                                             solid translucent screens, shutters, perforated panels or
                                                             trellises which have a maximum of 50% openings.

                                                             Editor's note—refer to figure AP3­1B
PO19                                                         AO19.1
Development, including mechanical plant, vehicle manoeuvring For developments that incorporate at least 800m2 of
and communal outdoor recreation uses:                        residential gross floor area, communal outdoor recreational
(a)   do not have an adverse effect on the amenity enjoyed facilities including swimming pools, spas and sports courts
      by users of adjacent or nearby premises through        are:
      emission of noise, light, fumes or smoke;              (a)    setback at least 12 metres from the boundary of land in
(b)   do not cause unreasonable disturbance to local fauna          a residential zone and screened by a 5 metre wide
      through light or smoke emissions.                             buffer densely planted with trees and shrubs including
                                                                    species from 1 metre to 8 metres in height; or
                                                             (b)    located internally to the arrangement of buildings on
                                                                    the site; and
                                                             (c)    not used between the hours of 9:00pm and 6:30am the
                                                                    following day

                                                             AO19.2
                                                             For a lit sports court:
                                                             (a)    the court is located at least 60 metres from the
                                                                    external wall of an existing or approved dwelling on
                                                                    adjoining or nearby premises (as measured from the
                                                                    centre line of the court); and
                                                             (b)    the vertical illumination resulting from direct, reflected
                                                                    or other incidental light emanating from the site does
                                                                    not exceed 8 lux when measured at any point 1.5
                                                                    metres outside the boundary and at any level from
                                                                    ground level upward; and


                                                                                                                  Page 288 of 1290
                                                                                                                         Page 15 of 18

Log in to download the original (62f8d7f274.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.