Performance outcomes Acceptable Outcomes
PO32 AO32.1
Mixeduse buildings are designed and operated to ensure: Business uses which operate outside the hours of 6:00am to
(a) business uses manage the potential impact on 9:00pm are designed and operated to minimise impacts on
residents, including impacts associated with: the amenity of residents of mixeduse buildings.
(i) visual and acoustic privacy;
AO32.2
(ii) safety and security; and
Residential uses are designed to incorporate suitable noise
(iii) lighting. attenuation and privacy measures to reduce amenity impacts
(b) residential uses do not limit the business opportunities from business uses.
of the site; and
(c) residential uses have reasonable privacy, security and AO32.3
private outdoor living space. The residential component of the development provides for:
(a) separate identifiable residential entries from entrances
for other building uses;
(b) clearly defined and safe pedestrian access to dwelling
units and accommodation units that are appropriately
lit, visible to others and directly accessible to units
from areas likely to be used at night;
(c) security measures such that building users do not have
access to areas that are intended for the exclusive use
or residents of, and visitors to, residential
accommodation;
(d) windows, balconies, terraces of each dwelling are
screened up to a minimum height of 1.7 metres from
the finished floor level where overlooking a habitable
room or private open space of another dwelling within 9
metres; and
(e) screening may incorporate solid translucent screens,
shutters, perforated panels or trellises which have a
maximum of 50% openings.
Editor's note—refer to figure AP31B and figure AP31C for
design outcomes for overlooking.
AO32.4
Dwellings provide:
(a) clearly identify private residential space by using
features such as low walls, changes in surface texture
or other landscape treatments.; and
(b) private open space or an open balcony directly
accessible from a habitable room:
(i) with a minimum area of 9m²,
(ii) with a minimum dimension of 2.5 metres; and
(iii) is clear of any utilities such as gas, water tanks
and air conditioning units.
Table 6.4.3.3 Criteria for assessment (part)