RESIDENTIAL USES CODE
Table 14-24 — For All Residential Uses
Specific Outcomes Probable solutions Proposal
14.46 Effects of use
Electricity supply infrastructure
O1 The development does not adversely S1.1 No solution provided. Complies
impact on existing or future electricity The proposed development for a
supply infrastructure; Multiple Housing – Type 4 Conventional
will not adversely impact on existing or
AND future electricity supply.
O2 All uses and works maintain an S2.1 Development for uses adjacent to Not Applicable
adequate safe distance from electrical or within 50m of an existing electricity
infrastructure including substations, substation incorporates noise
overhead powerlines, power poles and attenuation measures to mitigate noise
transformers. impacts;
AND
S2.2 Buildings and structures (including Complies
swimming pools, sheds, tennis courts or No buildings or pools will be constructed
outbuildings) are not constructed under under overhead electricity lines or within
overhead electricity transmission lines, electricity easements.
or within electricity easements;
AND
S2.3 A minimum separation distance is Complies
maintained from the electricity Minimum separation distances are
transmission line to the closest boundary achieved.
of habitable buildings and child activity
areas, as follows—
a) 20m for transmission lines up to
132kV;
b) 30m for transmission lines between
133kV and 275kV; and
c) 40m for transmission lines greater
than 275kV.
Hot Water Systems
O3 Hot water systems are installed and S3.1 All hot water systems installed Complies
operated to support the efficient use of are— An appropriate hot water system will be
natural resources and minimise a) solar systems; or installed.
consequent pollution such as b) electric heat pump systems; or
greenhouse gas emissions. c) natural gas or LPG systems; or
d) any combination of a), b) or c).
Water supply and conservation
O4 On-site water storage is designed S4.1 & S5.1 For a Class 1 building Not Applicable
and operated to support the efficient other than a Detached house or The site is within a reticulated water
use of water; Multiple Housing Type 1, outside a area.
reticulated water service area, a
AND rainwater tank is to be installed with the
following minimum storage capacities—
O5 On-site water storage is adequate a) Where no more than 3 bedrooms –
for occupants every day use and fire 45,000 litres; or
fighting purposes. b) Where more than 3 bedrooms –
60,000 litres;
AND
c) There is to be on the lot a dam,
swimming pool or water tank accessible
for use by the fire brigade that contains
at least 5,000 litres of water.
Advisory note
The 5,000 litres required can be
included within the water required in
S4.2 or S5.1 providing it is accessible for
the purpose of fire fighting at all times
and not used for other domestic
purposes.
Erosion and sediment control
O6 Development does not cause erosion No solution provided. Complies
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Planning Report & Code Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.2 MB (small file)
- File type
No other editions are linked here.