Original source · versioned page text
Approved Reference Documents - 132001.210127.3
Very large file (23.3 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Bushfire Hazard Assessment & Management Plan v2 NCES REF: J000542 Lot 9 on RP225312 ~ 100 Cooyar Street, Noosa Heads society will not accept this risk and measures are to be put in place to reduce risks to at least a tolerable level. Section 9.4 of the QFES Bushfire Resilient Communities 2019 references radiant heat flux exposure of <10kW/m? on the development footprint plan as generating an Acceptable to Tolerable level of risk for vulnerable uses. AS/NZS ISO 31000:2018 defines ‘Likelihood’ as the chance that something might happen. Likelihood can be defined, determined, or measured objectively or subjectively and can be expressed either qualitatively or quantitatively (using mathematics). The following ‘likelihood’ categories for the probability of the assessed bushfire attack mechanisms impacting the assessment area have been adopted within this assessment: e Likely - Will probably occur. ¢ Unlikely - Could occur but doubtful. The determination of whether a bushfire event is likely or unlikely to occur (i.e., impact the site) has been based on the relative position of hazardous vegetation to the site. Hazardous vegetation located upwind of the site under typical south-east Queensland (SEQ) seasonal fire winds from the north to north-west to west to south-west are deemed to be exposed to a ‘likely’ Probability of impact. Hazardous vegetation located downwind of the site under typical SEQ seasonal fire winds are deemed to be exposed to an ‘unlikely’ probability of impact. 4.2 Risk from Identified Hazardous Vegetation Hazardous vegetation is positioned to the north, south, and east of the development. The likelihood of a fire head approaching from these directions is typically considered unlikely, given dominant regional fire weather winds are typically derived from the north-west to west to south-west in SEQ. A fire front being directed by such winds could be expected to burn approach should be adopted, and the likelihood risk assigned as likely meaning that a fire impacting the site will probably occur at some time in the future. ¢ 47.1m to Sub Unit 1 (VHC 22.1); ¢ 38.4m to Sub Unit 2 (VHC 29.2): and ¢ 31.6m to Sub Unit 3 (VHC 34.5). Figure BF04 — Setback Requirements has been Prepared to depict the position of the <10kW/m? RHF contour emanating from the edge of the NSC firebreak Surrounding the site vs. the proposed development footprint. The majority of the proposed development occupies the existing building footprint with only the southern extent of the proposed building extending beyond the existing development footprint. The Proposed development footprint intercepts the vulnerable use <10kW/m? RHF setback requirement/contour to the south by a maximum of approximately 7.8m and to the east by amaximum of approximately 6m. The proposed degree of separation therefore exposes the future building to >10kW/m2 RHF to the east and south. Consequently, further modelling was undertaken to identify the specific radiant heat flux acting on the building. The modelling (refer Appendix 4 for full transcripts) identified the proposed separation exposes the building to: ¢ 7.47kWim? RHF from VHC 22.1 to the north; a © 2023 21 Bee emme
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.