Fire Safety Strategy – Bushfire Fire Spread Prevention 100 Cooyar Street, Noosa Heads QLD 4567 3 FIRE SAFETY RECOMMENDATIONS 3.1 General Note that all other items of fire and life safety, where not identified being part of the Bushfire fire safety strategy, are to be in accordance with the Deemed-to-Satisfy provisions of the BCA Volume 1 2019 or relevant standard at the time of design. 3.2 Fire Safety Systems and Equipment The bushfire assessment considers the provision of the following services and equipment: 1. All external walls are to be of non-combustible construction in accordance with BCA Clause C1.9 and Specification C1.1. 2. The roof of the building including the eaves detail are required to be non-combustible. 3. The following recommendations are to be applied to the southern and eastern elevations of the building, refer Figure 6. 3.1. No combustible external attachments including trellises, blinds, shutter, pergolas or the like are permitted to be attached to the external face of the building along the southern and eastern elevations. 3.2. All windows provided to the building are be fixed non-openable windows. 3.3. Any openable windows or doors are to be shielded via a fire attenuation mesh, e.g. Crimsafe. Any fire attenuation mesh shall be installed to the outside of the openings in accordance with the requirements of the tested system and shall be proven to have a radiation attenuation of at least 30%. 3.4. Balconies along these elevations shall be shielded via the same fire attenuation mesh system. Provided that fire attenuation screens are provided, sliding doors and curtains are permitted behind them. 4. All other aspects of the building are to be in accordance with the BCA Deemed-to-Satisfy provisions, including: 4.1. FRLs in accordance with the requirements of BCA Type B construction, noting the relevant items above; 4.2. Fire hydrant system in accordance with E1.3 and AS 2419.1; 4.3. Fire sprinkler system in accordance with E1.5 and AS 2118.1; 4.4. Fire extinguishers in accordance with BCA Clause E1.6 and AS 2444; 4.5. Smoke detection and alarm system in accordance with BCA Specification E2.2a. 4.6. Emergency Lighting and Exit Signage as required. 3.3 Maintenance Fire and life safety systems shall be maintained in accordance with the relevant Australian Standard to ensure performance and reliability in the event of an emergency. Maintenance of the surrounding vegetation area shall be followed with a protocol implemented such that the extent of the current vegetation as assessed by the NCES report does not encroach towards the building envelope. The following systems and physical building components shall be maintained in accordance with AS 1851-2012. • Fire hydrant system; • Fire extinguishers; • Fire sprinkler system; • Smoke detection and alarm system. Emergency and exit lighting shall be maintained in accordance with AS 2293.1. P a g e 16 | 18 Project Number: WBFE965-001-2023 Date: 22/03/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.