SUPERSEDED - Negotiated Decision Notice 132008 176 05

of 38

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                        trap. The drain outlet must be designed to prevent storm water entry to the sewerage
                        system.
                        Energy & Water Efficiency
                 81.    All hot water systems installed shall be either solar systems; electric heat pump systems;
                        or gas systems (LPG or natural).
                 82.    All new kitchen, laundry and bathroom fittings shall comply with the AAA Water
                        Conservation Rating System as defined by the AS/NZS 6400 (Water Efficient Products
                        - Rating and Labelling 2003) and AS/NZS 3500 (National Plumbing and Drainage
                        Standard Part 1.2), or current equivalent standards as may apply, with toilets to comply
                        with the AAAA Water Conservation Rating System. All new tap ware and shower roses
                        shall not exceed a maximum flow of 9 litres per min. Dishwashers and washing machines
                        are excluded from this requirement.
                 5.     REFERRAL AGENCIES

                 The referral agencies applicable to this application are:

                  Referral Status       Referral Agency and Referral Trigger                    Response
                                        Address

                  Concurrence           SARA at DILGP SARA        Schedule 10, Part 9,          The agency
                                        at DILGP Via MyDAS2       Division 4, Subdivision 1,    provided its
                                        at https://prod2.dev-     Table 1 – Protection of       response on 26
                                        assess.qld.gov.au/suite   State transport networks      October 2023
                                        / (for assistance,        - Development                 (Reference No.
                                        contact DILGP at 5352     exceeding the threshold       22070). A copy of
                                        9701 or                   in LGA2                       the response is
                                        email:SEQNorthSARA        Schedule 10, Part 10,         [email protected]     Division 3, Subdivision 3
                                        urrenceSARA               – Development in SE Qld
                                                                  Koala Habitat Area

                 6.     ADVISORY NOTES

                 The following notes are included for guidance and information purposes only and do not form
                 part of the assessment manager conditions:
                        Building and Construction Industry (Portable Long Service Leave) Levy
                 1.     The QLeave levy must be paid prior to the issue of a development permit where it is
                        required. Council will not be able to issue a Decision Notice without receipt of details
                        that the Levy has been paid.
                        Co-ordination of Operational Works Assessment
                 2.     Additional application fees apply to Operational Work applications where the different
                        aspects of the works are lodged separately. Significant savings in application fees will
                        result if all works are lodged in a single application.
                        Qualified Person
                 3.     For the purpose of preparing a Geotechnical Report, and for certifying geotechnical
                        stability for the development, a qualified person is considered to be a person who:
                        a.      is a Registered Professional Engineer of Queensland (RPEQ); and
                        b.      has a degree in civil engineering or engineering geology; and
                        c.      has a minimum of 5 years experience in the field of geotechnical engineering or
                                engineering geology.



                                                                                                        Page 14 of 38
Document Set ID: 23613543
Version: 2, Version Date: 04/03/2025
Log in to download the original file

SUPERSEDED - Negotiated Decision Notice 132008 176 05.pdf · 2.3 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.