Council archive · source document
Decision Notice DBW25 0118 · DBW25/0118
Building Height
4. The maximum height of the development must not exceed 8 metres above the ground level
and 9 metres where a pitched roof is proposed.
Car Parking
5. A minimum of 3 car parking spaces must be provided on site and made available and
accessible at all times for residents.
Environment
6. Sediment or any other material including building materials or waste products must not be
deposited or released into the road reserve, stormwater drain or adjacent properties.
Earthworks
7. All cut and fill must not exceed 2.0 metres in depth relative to natural ground level as detailed
on the approved plans.
8. All excavation/fill and associated batters must be contained entirely within the subject site
unless written permission from the respective landowner(s) is provided to Council. All
earthworks must be undertaken in accordance with the provisions of Australian Standard
AS3798: Guidelines on Earthworks for Commercial and Residential Developments.
9. All retaining walls must be designed and constructed in accordance with the planning scheme
and must be certified by an RPEQ where exceeding 1.0m in height.
10. All earthworks must include the installation and maintenance of appropriate erosion and
sediment control measures. Prescribed Water Contaminants (as defined in Schedule 10 of
Environmental Protection Regulation 2019) must not be released from the site or to waters
within the site, or be likely to be released should rainfall occur, unless all reasonable and
practicable measures are taken to prevent or minimise the release and concentration of
contamination.
11. Earthworks required on site must be carried out in accordance with Council’s Planning
Scheme Policy PSP6 - Engineering Design Standards, so as not to cause the additional
ponding of water on any adjoining lands or concentrate or direct overland flow on to an
adjoining property.
Stormwater Drainage
12. Stormwater runoff from the development must be disposed of on-site without causing scour
or damage to the subject site or any adjoining property.
Water Supply
13. The approved dwelling must be serviced with a rainwater tank having a minimum storage
capacity of no less than 60,000 litres.
Waste Water Treatment and Disposal
14. The dwelling must be provided with an on-site wastewater treatment and effluent disposal
system having a capacity sufficient for the use*.
*(Refer to Advisory Note)
DEMOLITION WORK
Codes of Development
15. Unless specifically conditioned otherwise, all works must comply with the relevant acceptable
solutions as contained in the Waste Management Code and Water Quality and Drainage
Code of the Noosa Plan 2020.
Page 3 of 7
Document Set ID: 24199509
Version: 4, Version Date: 08/10/2025
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Decision Notice DBW25 0118.pdfRelated documentApplication case desk ↗
About this file
- File size
- 156 KB (small file)
- File type
No other editions are linked here.