Bushfire Hazard Assessment & Management Plan v4 - 7 Triller Court, Pomona
Attached to the e-mail RAL21/0022 - 7 Triller Court_ Pomona - Response to Further Advice Matters & Change to app (1 Lot into 4).
Plans and drawings: the text below has words only, no drawings.
Bushfire Hazard Assessment & Management Plan v4 NCES REF: J000841 Lot 4 on SP320405 – 7 Triller Court, Pomona To ensure emergency access and operational space for firefighters the subdivision layout results in lots that are sited so that they are separated from the closest edge to the adjacent medium, high or very high potential bushfire intensity area by a distance that achieves a radiant heat flux level of 29 kilowatt per square metre or less. To facilitate safe evacuation during a bushfire event, include a development footprint plan that is located within 60 metres of the street frontage and sited to enable a route between the development footprint plan and the street frontage with a gradient that does not exceed of 12.5 per cent. Where reconfiguring a lot creating lots of 2000 square metres or less (i.e., Lots 4-8): To ensure emergency access and operational space for firefighters the subdivision layout results in lots that are sited so that they are separated from the closest edge to the adjacent medium, high or very high potential bushfire intensity area by a distance that achieves a radiant heat flux level of 29 kilowatt per square metre or less. 1. The building envelope, if identified at RaL stage, or 2. Where a building envelope is not identified, at all the lot boundaries. Compliance with Assessment Benchmark 4 can be attained where building envelopes are sufficiently separated from the nearby hazardous vegetation so that a radiant heat flux level at any point on the building or envelope does not exceed 29 kW/m². 5.2.3 Radiant Heat Flux Setbacks Determination of the setbacks required to satisfy Assessment Benchmark 4 can be identified from the quantitative modelling output presented in Section 3.6 herein. The output results from Plates 9-11 can be used to identify the setback requirements to achieve the <29 kW/m² radiant heat flux SPP requirement. The required setbacks are shown in Table 2. Table 2 – Radiant Heat Flux Minimum Setbacks to secure <29kW/m² VHC Direction <29 kW/m² Setback* and slope 9.1 north - 7° 23.9m 9.1 south - 9° 25.7m 9.1 west - 1° 17.9m * Source – Flamesol Minimum Distance calculator Building envelopes have been nominated within each of the new allotments which are provided with sufficient setback to the adjoining hazardous vegetation to comply with Assessment Benchmark 4. It is noted that Lot 7’s BLE is currently flanked by the low threat sub unit 4 (cleared understorey) to the north however, given this area is also mapped as a Koala Habitat Area (core) under the State mapping, the BLE has been positioned a minimum of 24m from the edge of the unit, to account for potential understorey regrowth that may arise therein. As such the APZ for Lot 7 does not rely on any vegetation clearing, including mowing of existing cleared understorey conditions, within the mapped KHA. Setbacks available within the allotments are to be prescribed as dedicated APZs and are to be maintained in accordance with the landscape criteria specified in Section 5.6 for the life of the development or until such time as an alternative setback can be justified (i.e. where assessment methodologies change). 5.2.4 Recommended APZ’s Lots 4-6 A minimum 24m wide APZ is recommended to be applied between the building envelopes © 2023 22
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.