Bushfire Hazard Assessment & Management Plan v4 - 7 Triller Court, Pomona

Attached to the e-mail RAL21/0022 - 7 Triller Court_ Pomona - Response to Further Advice Matters & Change to app (1 Lot into 4).

of 47

Page text read automatically using OCR, there may be inaccuracies

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
Bushfire Hazard Assessment & Management Plan v4                                        NCES REF: J000841
Lot 4 on SP320405 – 7 Triller Court, Pomona



2    Site Description

2.1 General
The site comprises an irregular shaped allotment located to the south of the Pomona town centre
and has area of approximately 3.6ha. Existing low density residential allotments exist along Triller
Court to the east, with Tuchekoi National Park adjoining the site’s north-western boundary.
Vegetated rural properties adjoin the site’s southern boundary.
The site is dominated by mown grass with mature trees located within the north-western site extent.
The property contains an existing dwelling with associated infrastructure (sheds, carport etc.). The
site is zoned as Low Density Residential in the eastern extent and Rural in the western extent under
The Noosa Plan 2020. Plate 2 depicts the site’s position in the landscape and the extent of existing
development.




                                      Plate 2 – Site Context (Source: Nearmap)

2.2 Topography
The slope of the land is a major determinant of fire behaviour, particularly the slope of the land under
vegetation that contributes to bushfire hazard. Fire burns faster as it travels up slope, via preheating
of unburnt fuels ahead of the fire, increasing the rate of spread and fireline intensity. Conversely,
fires move more slowly as they travel downslope. Fireline intensity (kW/m) is a function of the rate
of spread (QFES 2019).
The site is located on sloping undulating terrain with slopes of approximately 5 degrees. A broad
ridgeline runs through the site on a roughly north-east to south west alignment. Slopes descend from
the ridgeline in a northerly and southerly direction. The site reaches a topographic high of
approximately 124m AHD in the south-west corner and declines towards the north-east to a
topographic low of approximately 93m AHD.
Plate 3 depicts topography conditions within and adjacent to the site.




© 2023                                                    5
Log in to download the original file

Bushfire Hazard Assessment & Management Plan v4 - 7 Triller Court, Pomona.pdf · 4.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.