Appendix 5 - Air quality assessment report
2 Assessment Criteria
The key air quality indicators for assessing impacts from service stations include volatile organic
compounds (VOCs) and odour.
The Noosa Plan (2018) does not specify criteria for air quality impact assessments. Therefore,
reference has been made to criteria for VOCs as presented in the Environmental Protection (Air)
Policy 2008 (EPP Air). Where relevant criteria is not provided in the EPP Air, reference has been made
to the Brisbane City Council (BCC) 2014 Service Station Code. For odour, reference has been made to
criteria presented in the Odour Impact Assessment for Developments Guideline (2013) published by
the Department of Environment and Heritage Protection (now Department of Environment and
Science, DES). Table 2.1 summarises the criteria adopted for the target compounds considered in the
air quality assessment.
Table 2.1 - Air Quality Quality Criteria
Air Quality Criteria
Compound Averaging Period Outcome
mg/m3
Protecting aesthetic
1100 30 Minutes
environment
Toluene1
4100 24 Hour Health and well being
410 Annual Health and well being
1200 24-hour Health and well being
Xylene1
950 Annual Health and well being
1
Benzene 10 Annual Health and well being
2
Cyclohexane 19,000 1 Hour Health and well being
2
n-Hexane 3,200 1 Hour Health and well being
2
Ethylbenzene 8,000 1 Hour Health and well being
Protecting aesthetic
75 30 Minutes
Styrene1 environment
280 7 days Health and well being
2
Cumene 21 1 hour Odour
0.5 OU for tall stacks
1 hour,
Odour3 2.5 OU for ground level Odour
99.5th percentile
and wake-affected plumes
1
Criteria based on Environmental Protection (Air) Policy 2008
2
Criteria based on Brisbane City Plan 2014 Industrial Amenity Overlay Code
3
Criteria based on the Department of Environment and Heritage Protection (EHP) Odour Impact Assessment from Developers
Guide (2013)
Air emissions from the underground tank vents are considered wake affected due to the presence of
nearby buildings. Therefore, the 2.5 OU criteria is applicable to the tank vents. All other air emission
sources (e.g. refuelling) are at ground level hence, the 2.5 OU criteria is applicable for these sources.
Page 9 of 35
Belo Developments- Air Quality Assessment - Proposed Service Station, Noosaville
/Network/Projects/4694.2/Reporting/4694.2-AirReport02.odt
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.