Appendix 5 - Air quality assessment report

of 35

Page text shows just the words. Original shows the document exactly as it was published.

3           Air Emission Data Data
3.1         Service Station Air Emission
3.1.1       Potential Air Emission Sources
Air emissions from the proposed service station are expected to occur from a number of different
sources and activities. These include:

⚫ refuelling areas (during filling of cars, and ‘whoosh’ emissions during removal of fuel cap on
    vehicle);

⚫ tank breathing from underground tanks via the vent pipes;
⚫ bulk filling of underground tanks (emissions occur when vapour in the head space is displaced as
    tank filling occurs); and

⚫ other fugitive emissions such as spillage.
The key air quality indicators associated with the above sources are general odour and Volatile
Organic Compounds (VOCs) which include compounds such as benzene, toluene, xylene, styrene,
cyclohexane, n-hexane and ethylbenzene. Exposure to elevated concentrations of VOCs are related
to health and nuisance odour impacts.

In relation to bulk filling, when a vapour return system is used on the road tanker to return vapours
to the tanker rather than allowing them to be emitted to the atmosphere, emissions can be reduced
substantially (in the order of 95%). This type of mitigation is called Phase 1 vapour recovery. Phase 1
vapour recovery is proposed to be installed at the site. Phase 2 vapour recovery, which reduces
emissions during vehicle refuelling, is also proposed to be installed at the site.

Table 3.1 presents a summary of the proposed service station operating data. Figure 4.5 in Section
4.4 presents the location of the air emission sources.

Table 3.1 - Service Station Operating Data

           Parameter                                                     Details
    Proposed Operating Hours                                        5 am to 10 pm
            Fuel Sales                                                6.3 ML/year
           Vent Stack                                                       4m
  Filling Stations/Petrol Bowsers                 5 bowser ranks (2 filling points each side)
          Storage Tanks                                             ULP and diesel
         Fuel Deliveries                                    Maximum 40 kL per hour
        Emission Controls                              Phase 1 and 2 Vapour Recovery




                                                                                                                             Page 10 of 35
                                                       Belo Developments- Air Quality Assessment - Proposed Service Station, Noosaville
                                                                                   /Network/Projects/4694.2/Reporting/4694.2-AirReport02.odt
Log in to download the original file

Appendix 5 - Air quality assessment report.pdf · 3.8 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.