LIGHTING KEY: NOTES:
LED BATTEN LIGHT S STAIR WALL LIGHT 1. PROVIDE 3 PHASE SUPPLY FROM STREET.
L
LED STRIP LIGHTING E EXTERNAL WALL LIGHT
2. PLACE ALL LIGHT SWITCHES AT 1100mm AFFL.
DL
DIRECTIONAL LED STRIP D UP/DOWN WALL LIGHT
LV 6. ENERGY EFFICIENT LIGHTING TO BE INSTALLED AS OUTLINED IN THE
LV DOWNRIGHT P ENERGY RATING ASSESSMENT.
POOL/POND LIGHT
LED DOWNLIGHT H 3 in 1 EXHAUST FAN/HEATER 3. SEE JOINERY DETAILS FOR LOCATION & EXTENT
P OF LED STRIP LIGHTING.
PENDANT LIGHT
EXHAUST FAN
G 4. PROVIDE DIMMERS TO ALL PENDANT LIGHTING.
LV GARDEN LIGHT
MOTION SENSOR
U
RECESSED LED UP LIGHT
SD SMOKE DETECTOR
W
POND LIGHT IMMERSED TD THERMAL DETECTOR
SP * TOTAL INTERNAL DIMMABLE LED STRIP LIGHTING APPROXIMATELY - m
DIRECTIONAL SPOTLIGHT X SWITCH
* TOTAL EXTERNAL LED STRIP LIGHTING APPROXIMATELY - m
INTERNAL WALL LIGHT 2 2-WAY
* TOTAL EXTERNAL RGB LED STRIP LIGHTING APPROXIMATELY - m
3 3-WAY
D DIMMER * TOTAL EXTERNAL DIMMABLE RGB LED STRIP LIGHTING APPROXIMATELY - m
CEILING FAN
SWITCHWIRE CONFIRM ALL LENGTHS ON SITE
CLIENT EXISTING
PENDANTS-
LARGE X 1
X XX
1000 1000
P
D BED 2 D
STUDY
D D
D D
D D
DD
XX X
XX
ENSUITE
D LED TO UNDERSIDE OF
LED TO UNDERSIDE OF ROBE NICHE CUPBOARD 4.4m
D D
XX X X
L L
NICHE CUPBOARD 3.5m (SJD)
EACH ENSUITE (SJD) DN SP-D
L ROBE
SP-D
DIMMABLE LED TO SP-D SP-D
ENSUITE UNDERSIDE OF EAVE SP-D
XX X 9.8m (SJD)
DIMMABLE LED TO TOP OF ENSUITE
SCREEN/UNDERISDE OF
L
SURROUND 9.8m (SJD)
D BED 3 D XX
L-D DD
SP-D LED TO TOP OF
NICHE RECESS 0.7m
(SJD)
D D SP-D DDD SP-D HALL SP-D SP-D
222
XXX
D
X
XX X
L-D
D2
1000 1000 X L
X XX ROBE
DN (HANDRAIL) MASTER 2
LINEN SP-D SP-D SP-D
1000 1000
XX X
HANDRAIL LIGHTS SWITCH 2
WAY TO ALL LEVELS (LOWER & LED TO ROBE FLOOR SENSOR
GROUND, GROUND & UPPER) 3.7m (SJD) UNDER KICK
UPPER FLOOR LIGHTING PLAN
SCALE: 1 : 100
CLIENT: Judy & Michael KLOBAS PROJECT: PIPIS
www.chriscloutdesign.com.au GENERAL NOTES:
Use written dimensions only. DO NOT scale drawings. Contractors SITE ADDRESS: Lot 696 on SP279875 8 Stevens Street Sunshine Beach QLD 4567
PO BOX 135, NOOSAVILLE, QLD 4566 to verify all dimensions on site prior to commencing works. Site
E: [email protected] location in accordance with engineers details. These drawings are to DRAWING TITLE: LIGHTING PLAN
P: (07) 54748 107 be read in conjunction with engineers design and details, the
DATE: 08/08/19 SCALE: 1 : 100 @ A2 DRAWN BY: C.CLOUT
F: (07) 54748 108 BSA LICENCE: 1127508
accompanying building specification and schedule of finishes. If in
doubt, please request clarification. DO NOT ASSUME. ISSUE: WORKING DRAWINGS FOR CONSTRUCTION
WD10.1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Noosa Council Amendment Request MCU18-0001.01.pdfRelated documentApplication case desk ↗
About this file
- File size
- 12.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.