KEY: NOTES:
MAIN SWITCHBOARD 1. PROVIDE 3 PHASE SUPPLY FROM STREET.
SUB BOARD 2. PLACE ALL POWER POINTS AND OUTLETS TO
NETWORK DISTRIBUTOR SUIT CABINETRY AND/OR FITTINGS.
REMAINING POWER POINTS AND OUTLETS TO MS
DOUBLE GPO BE MOUNTED 300mm AFFL.
300
SINGLE GPO 3. PROVIDE SUPPLY POWER TO A/C UNITS AS
DOUBLE DATA/PHONE OUTLET REQUIRED.
SINGLE DATA/PHONE OUTLET 4. PROVIDE SEPERATE CIRCUITS FOR FRIDGES. HDMI
(HARDWIRED
CAT
WITH TIMER
300
TV OUTLET 1200 TBC
SJD)
HTR
INTERCOM 300 SOUND BAR & 300 300
SUBWOOFER
SECURITY SENSOR
DOME CCTV CAMERA GYM BATH LAUNDRY GARAGE
HDMI HDMI CABLE
CAT CAT CABLE
CEILING
PIN PIN PAD MOUNTED
SPK CEILING MOUNTED SPEAKER 1000 1000
300 300
KP 1200
V VACUMAID WALL INTLET
ELECTRICAL PLAN SHOULD BE READ IN MEDIA/ MS
VACUMAID POWER UNIT 300/1200
VAC CONJUNCTION WITH JOINERY PLANS FOR STUDY HALL
MOTORISED BLINDS MORE DETAILED POWER POINT
SD SMOKE DETECTOR PLACEMENT
MS
KP CEILING
AUTOMATION CONTROL 1200 MOUNTED
T TOUCH PANEL DOME
TH THERMOSTAT
AP
SECURITY SWITCH
300 300 CEILING
CEILING MOUNTED WAP MOUNTED
(WIRELESS ACCESS POINT)
900+ USB 900 STORE
300
FOYER
PROVIDE POWER TO WINE CELLAR
CELLAR - CONFIRM SD 300/1100
REQUIREMENTS WITH
CONTRACTOR 300
LIFT SERVICES 2000
300 300 1100
PROVIDE POWER AND DATA FOR SERVICES AS
REQUIRED. RACK FOR CCTV, ALARM PANEL, PHONE
LEED IN, MODEM & DATA PANELS & SWITCHES
PROPOSED LOCATION FOR LIFT CONTROL
BOX - CONFIRM WITH LIFT MANUFACTURER
PROVIDE POWER FOR LIFT,
REFER TO MANUFACTURERS
SPECIFICATIONS
LOWER FLOOR POWER PLAN
SCALE: 1 : 100
KP
1200
PROVIDE POWER TO PROVIDE POWER TO
SERVICES SERVICES
POOL
600 A/C HW SERVICES HW
800 MS
(900) CAT
HDMI (900)
300 300
1200 TBC SD
SOUND BAR &
SUBWOOFER
1200 1200
300+USB 300+USB
CEILING
MOUNTED
DOME
1100
SD
300
300
MS
CEILING
CEILING MOUNTED
MOUNTED HTR
1500 1500 (HARDWIRED DOME
DOME (IN CBD) (IN CBD)
WITH TIMER
SJD) 300
KP
MS
1200 300
CEILING
MOUNTED SD
700
DOME 300 (UNDER
(DW) BENCH)
MS
1200 KP KP 300/1200
600 (MW)
LIFT /1100
600 2000 2000 1200 800/2100
AP
(UNDER 1100 1100 (FR) (FRZ) (OV) (CT/RH)
1100
BENCH)
PROVIDE POWER FOR LIFT,
REFER TO MANUFACTURERS
SPECIFICATIONS
GROUND FLOOR POWER PLAN
SCALE: 1 : 100
CLIENT: Judy & Michael KLOBAS PROJECT: PIPIS
www.chriscloutdesign.com.au GENERAL NOTES:
Use written dimensions only. DO NOT scale drawings. Contractors SITE ADDRESS: Lot 696 on SP279875 8 Stevens Street Sunshine Beach QLD 4567
PO BOX 135, NOOSAVILLE, QLD 4566 to verify all dimensions on site prior to commencing works. Site
E: [email protected] location in accordance with engineers details. These drawings are to DRAWING TITLE: POWER PLAN
P: (07) 54748 107 be read in conjunction with engineers design and details, the
DATE: 08/08/19 SCALE: 1 : 100 @ A2 DRAWN BY: C.CLOUT
F: (07) 54748 108 BSA LICENCE: 1127508
accompanying building specification and schedule of finishes. If in
doubt, please request clarification. DO NOT ASSUME. ISSUE: WORKING DRAWINGS FOR CONSTRUCTION
WD11.0
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Noosa Council Amendment Request MCU18-0001.01.pdfRelated documentApplication case desk ↗