PLANNING & ORGANISATION COMMITTEE MEETING AGENDA                             9 DECEMBER 2014


    26.   Certification must be submitted to Council from all relevant service providers which
          certifies that the development has met the requirements of this Decision Notice and
          all applicable legislation at the time of construction.
    Easements
    27.   Easements for inter-allotment drainage within Lots 26-28 which encompass the
          constructed drainage structures.
    28.   Unless otherwise agreed in writing by the relevant service provider, any public or third
          party infrastructure located on the subject site must be placed within an easement
          registered against the title of the property.
    29.   All easements must be designed in accordance with the planning scheme and
          granted at no cost to the Grantee. Where the Grantee is Council or a service
          authority, the easement documentation must be in accordance with the Grantee’s
          standard easement terms. Draft easement documentation must be submitted to
          Council for endorsement.
    30.   All works must be kept clear of any existing or proposed easements on the subject
          land, unless agreed otherwise in writing by the Grantee.
    Earthworks and Retaining Walls
    31.   All fill and associated batters must be undertaken in accordance with an Operational
          Works approval, and contained entirely within the subject site unless written
          permission from the respective landowner(s) is provided to Council.
          UNITYWATER
          The following Unitywater conditions are applied in accordance with the South East
          Queensland (Distribution and Retail) Restructuring Act 2009 and Unitywater’s Interim
          Connections Policy. The conditions below form part of a water connection aspect
          which are taken to be a water approval for a staged connection. Any future
          applications must be made to Unitywater under South East Queensland (Distribution
          and Retail) Restructuring Act 2009. Unitywater can be contacted as follows:
          Phone:     1300 0 Unity (1300 086 489)
          Email:     [email protected]
          Web:       www.unitywater.com
    32.   Reticulated water must be provided to each lot in the development. This must
          include:
          a.    Ensuring that internal water pipes are wholly contained within the lot they will
                serve.
          b.    An approved water meter for each lot in accordance with Unitywater and SEQ
                Standard Drawings.
          c.    Provision of a water service from the existing 100mm diameter water main to
                service located in Blue Wren Place to service each lot within the proposed
                subdivision in accordance with Unitywater and SEQ Standard Drawings.
          d.    Water meters must be located on alternative boundaries to electrical pillars
          e.    The fire-fighting demand on Unitywater’s water supply system from the
                development must not exceed 15 litres per second
    33.   Reticulated sewerage must be provided to each lot in the development. This must
          include:
          a.    Ensuring sewer house drains are wholly contained within the Lot they will serve.
          b.    Provision of sewerage infrastructure to within the property boundaries of each
                Lot within the proposed subdivision.

                                                                                   Page 9 of 134
Log in to download the original file

2014-12-09 Planning & Organisation Committee Agenda(PDF, 12MB).pdf · 13.1 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.