Vegetation Protection
40.   All trees to be retained shall be clearly defined on all drawings and clearly marked on
      site to prevent any damage occurring to these trees.
41.   Any works required within the drip zone of any trees to be retained shall be carried out
      by hand, not by machinery.
42.   The internal driveway (or any other form of hard pavement for that matter) within the drip
      zone of any trees on site to be retained shall be designed to allow the flow of water
      through the pavement or be designed to direct stormwater runoff to the trees root
      system. To this extent the uncovered visitor spaces towards the frontage of the
      development may be able to incorporate Grass Rings or a similar device that allows
      water penetration.
43.   All pavements shall be constructed so as not to damage the root system of any trees to
      be retained and in this regard temporary fencing shall be provided around the trees
      during construction to help protect them.
44.   Plans shall be submitted to the Council for approval that clearly show the type and
      extent of pavements proposed, how they comply with the above conditions and also
      illustrating any temporary fencing to protect the trees prior to obtaining a Development
      Permit for Operational Works.
Frontage Works
45.   Footpath improvements such as topsoiling, grassing, and tree planting are required to
      the Serenity Close frontage of the site (if not already provided) in accordance with
      Planning Scheme Policy PSP1 Landscaping Guidelines. Grass shall be couch, free of
                                                                                    %
      weeds.
46.   A new 1.5 metre wide concrete path shall be constructed along the Serenity Close
      frontage of the site (if not already provided) in accordance with Council's design
      standards and to an alignment that protects any significant vegetation or any
      underground services.
47.   All paths shall be designed and constructed to ensure pedestrian safety using non-slip
      materials and to produce an evenly graded surface finish.
Stormwater Drainage
48.   A stormwater management plan shall be prepared by a RPEQ, specialising in
      stormwater and water quality management incorporating the principles of the
      Environmental Management Plan for the Settlers Cove Development 23118DA, that
      demonstrates water reuse strategies, infrastructure capacity and effective treatment
      methodology. The use of rainwater harvesting tanks for irrigation purposes shall be
      incorporated in the overall design plans. These plans shall be submitted to Council for
      approval prior to obtaining a Development Permit for Operational Works.
49.   All stormwater drainage shall be collected on site and discharged so there is no net
      increase in stormwater runoff from the site.
50.   A stormwater holding tank shall be provided on site with a capacity to hold at least
      40,000 litres of water for the purpose of providing non-potable water supply to
      landscaped areas.
51.   On site swale drains will be required to capture and direct any overland stormwater
      runoff to the Infiltration Pits proposed on site. These swales shall be sized to carry a 3-
      month storm event and plans detailing their capacity, location, length, width and grades
      shall be submitted to Council for approval.




                                                                                 Page 7 of 15

Used in these records

About this file

File size
4.6 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

132005.699.1.05 - Application to Change to Existing Approval - (shows as 699.1.05 but should be .66.05).pdf · 4.6 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.