Original source · versioned page text
Skale plans
Attached to the e-mail Application and Design plans.
The original of this document is very large (12.1 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn¿ play your part - print on recycled paper 5m 4 3 2 1
PV solar system to be in accordance with specialist contractors design and
6 5 4 3 2 1 detail with no penetration fixing clamps to roof sheet. ELEVATION LEGEND
5 690 2 300 1 200 6 300 800 COLORBOND® steel BlueScope Lysaght barge flashing to detail. 230 x bw Concrete block wall to be in accordance with
top of roof flashing 31mm h3 treated primed timber fascia. structural engineers design and detail. Provide
150 x 50mm sawn hwd spotted gum blade posts and roof RL 9.64 Rockcote acrylic render system with sponge finish
beams. Provide 20mm dia powder coated spacers with M12 6.0° 600 and painted with selected colour in accordance with
galv. rods @750mm cts. u/s typical ceiling final colour selections to exposed wall surfaces.
8 570 top of window RL 8.57 Refer to Rockcote for full coating system details.
Ceiling RL 8.26
top of roof flashing cl1 Timber framed wall to be in accordance with
600
RL 7.59 structural engineers design and detail. Provide
450mm Heka Hood to be fixed in accordance with manufacturers 180mm Scyon Linea weatherboard cladding with
Timber framed soffit with 6.0mm Hardiflex
2 710
cl1 specifications.(www.hekahoods.com.au) aluminium corners installed in accordance with
sheeting installed in accordance with
manufacturers specifications. manufacturers specifications.
sfl cl2 Timber framed wall to be in accordance with
5 860 cl1 RL 5.86
structural engineers design and detail. Scyon™
First floor cl3 Axon™ 133 smooth wall sheeting to be installed in
90mm UPVC downpipes with Artplastics
classic downpipe flush joiners. accordance with manufacturers specifications.
top of roof flashing cl3 6.0mm HardiFlex cladding with 31 x 31mm primed
3 060
Timber framed wall to be in accordance with structural engineers design
RL 4.09 h3 treated cover battens @ 300mm cts.
and detail. Provide 180mm Scyon Linea weatherboard cladding with
cl1
rs2 aluminium corners installed in accordance with manufacturers
rs1 0.42mm COLORBOND® steel BlueScope Lysaght
specifications.
sfl TRIMDEK® roof sheeting @6 degree pitch to be
cl3 RL 2.80 fixed in accordance with manufacturers
2 800
Ground floor specifications. Roof framing to be in accordance
450mm Heka Hood to be fixed in accordance with manufacturers with structural engineers design and detail.
specifications.(www.hekahoods.com.au)
rs2 0.42mm COLORBOND® steel BlueScope Lysaght
TRIMDEK® roof sheeting @2 degree pitch to be
fixed in accordance with manufacturers
specifications. Roof framing to be in accordance
with structural engineers design and detail.
rs3 0.42mm COLORBOND® steel BlueScope Lysaght
hwd posts and exposed roof beams in accordance with structural TRIMDEK® roof sheeting @15 degree pitch to be
engineers design and detail. Posts & roof beams to have painted finish. 100 x 16mm H4 treated hwd paling undercroft screening with H4 treated
fixed in accordance with manufacturers
hwd posts and rails. Screening to have palings spaced with 75mm gap and
specifications. Roof framing to be in accordance
palings to each side of rails offset.
with structural engineers design and detail.
6 5 4 3 2 1 Timber framed decking stairs to have h4 treated timber structure in
accordance with structural engineers design and detail. Provide 86 x 19mm
150mm ½ round gutters in COLORBOND® steel to be fixed in accordance spotted gum decking (Standard & Better Grade) with Buildex® Dec-King®
with manufacturers specifications. Gutters to have 10mm spacers to fascia stainless steel self drilling decking screws to structure. Decking shall be
to provide overflow point. installed in accordance with Timber Queensland Technical Data Sheet 13.
Stairs to be in accordance with NCC 3.9.1. Provide spotted gum 50mm ROOF PLAN LEGEND
Handrail to have selected 316 stainless steel offset brackets, handrail to
comply with NCC 3.9.1.
Eastern Elevation
E 1:100
PV solar system to be in accordance with specialist
contractors design and detail with no penetration fixing Timber framed hwd stairs with open risers. Stairs to comply with NCC 3.9.1.
clamps to roof sheet.
0.42mm COLORBOND® steel BlueScope Lysaght Folded COLORBOND® steel apron flashing to be fixed in accordance with
TRIMDEK® roof sheeting to be fixed in accordance with manufacturers specifications. Builder to ensure anti capillary break is
manufacturers specifications. Roof framing to be in provided to wall in accordance with NCC 3.5.1.3.
accordance with structural engineers design and detail. Timber framed wall to be in accordance with structural engineers design
and detail. Provide 180mm Scyon Linea weatherboard cladding with
G F E D C B A aluminium corners installed in accordance with manufacturers
specifications.
150mm ½ round gutters in COLORBOND® steel to be fixed 5 320 3 090 10 470 1 900 7 700 3 600
top of roof flashing 150mm ½ round gutters in COLORBOND® steel to be fixed in accordance
in accordance with manufacturers specifications. 230 x RL 9.64
31mm h3 treated primed timber fascia. Gutters to have with manufacturers specifications. 230 x 31mm h3 treated primed timber
10mm spacers to fascia to provide overflow point. fascia. Gutters to have 10mm spacers to fascia to provide overflow point.
rs1 rs1 u/s typical ceiling
8 570 RL 8.57
Ceiling 290mm Concrete block wall to be in accordance with structural engineers
cl2 cl2 design and detail. Top course of block wall Lintel blocks unfilled as planter
Timber framed wall to be in accordance with structural bed. Provide Rockcote acrylic render system with sponge finish and painted
2.0°
2 710
engineers design and detail. Provide 180mm Scyon Linea cl1 cl1 cl1 cl1 with selected colour in accordance with final colour selections to exposed
weatherboard cladding with aluminium corners installed in wall surfaces. Refer to Rockcote for full coating system details. Planter to
accordance with manufacturers specifications. cl1 have 2x 40mm upvc drainage outlets and Emer-Proof Ecoflex Anti Root
cl1
cl2 cl2 waterproofing system. sfl
5 860 cl1 cl1 RL 5.86
cl1
First floor top of window cl2
RL 5.20
90mm UPVC downpipes with Artplastics
classic downpipe flush joiners.
3 060
2.0° cl1 cl1 cl1
sfl
2 800 RL 2.80
Ground floor
hwd posts and exposed roof beams in accordance with
structural engineers design and detail. Posts & roof beams Timber framed decking stairs to have h4 treated timber structure in
to have painted finish. accordance with structural engineers design and detail. Provide 86 x 19mm
spotted gum decking (Standard & Better Grade) with Buildex® Dec-King®
stainless steel self drilling decking screws to structure. Decking shall be
Timber framed wall to be in accordance with structural installed in accordance with Timber Queensland Technical Data Sheet 13.
engineers design and detail. Scyon™ Axon™ 133 smooth Stairs to be in accordance with NCC 3.9.1. Provide spotted gum 50mm
wall sheeting to be installed in accordance with Handrail to have selected 316 stainless steel offset brackets, handrail to
manufacturers specifications. comply with NCC 3.9.1.
100 x 16mm H4 treated hwd paling undercroft screening
G F E D C B A
with H4 treated hwd posts and rails. Screening to have Timber framed balustrade in accordance with NCC 3.9.1. with 138 x 42mm
palings spaced with 75mm gap and palings to each side of h3 treated primed rails & 66 x 42mm h3 treated primed cross braces.
rails offset. Balustrade to have aluminium mesh inset panels to feature timber structure.
Balustrade to be a min. 1000mm high above finished floor level.
Timber framed wall to be in accordance with structural engineers design
and detail. Provide 180mm Scyon Linea weatherboard cladding with
aluminium corners installed in accordance with manufacturers
specifications.
Northern Elevation
N 1:100
/Users/benthornton/Docs/Cadfiles/1901 - Seeto/Archicad/23072020/1901.pln
sbt designs pty ltd t/a
Skale Building Design builder Chris Fletcher
Director / Builder
project Residence lot no. 9 H Revised Construction issue 20/8/20
project number
Mobile: 0412 025 657 Squire Development Group Pty Ltd
for Dereke & Melanie Seeto plan no. 99140 G Revised Construction issue 23/7/20
1901
skale
0412 743 408 F Revised Construction issue 9/7/20
skale.com.au 71 Noosa River Drive drawn BT
E Revised BA issue 29/6/20
drawing number
building design
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at Noosa North Shore scale (A2) 1:100 Rev Details Date 2.2 H © Skale Building Design