Log in to see the plans as drawn¿ play your part - print on recycled paper 2.5m 2 1.5 1 0.5
Timber framed floor to be in accordance with structural engineers design and detail. Provide
20mm structural sheet flooring over joists installed in accordance with manufacturers
specifications.
Folded COLORBOND® steel apron flashing to be fixed in accordance with manufacturers
specifications. Builder to ensure anti capillary break is provided to wall in accordance with
NCC 3.5.1.3.
A B C D
3 600 7 700 1 900
Timber framed stairs to be in accordance with NCC 3.9.1. and manufacturers specifications.
Timber to be select grade blackbutt hwd treads and risers. Provide dressed select grade
blackbutt hwd handrail with selected 316 stainless steel offset brackets, handrail to comply 150 600
with NCC 3.9.2.
Timber framed wall to be in accordance with structural engineers design and detail. Provide
180mm Scyon Linea weatherboard cladding with aluminium corners installed in accordance
8 570 with manufacturers specifications.
Ceiling
0.42mm COLORBOND® steel BlueScope Lysaght TRIMDEK® roof sheeting to be fixed in
accordance with manufacturers specifications. Roof framing to be in accordance with
structural engineers design and detail.
Timber framed soffit with 6.0mm Hardiflex sheeting installed in accordance with 2.0°
manufacturers specifications. 575
150mm ½ round gutters in COLORBOND® steel to be fixed in accordance with Master suite Dressing
manufacturers specifications. 230 x 31mm h3 treated primed timber fascia. Gutters to have
10mm spacers to fascia to provide overflow point.
5 860
First floor
Aluminium screens to be installed in accordance with specialist contractors design and Outdoor
350
2 710
detail. Balustrade
RL 4.85 Dining Lounge
90mm UPVC downpipes with Artplastics classic downpipe flush joiners.
1 610
150mm hwd posts in accordance with structural engineers design and detail. Posts to have
sfl
painted finish. ffl - Decking RL 3.90
RL 3.85
H
Timber framed decking stairs to have h4 treated timber structure in accordance with
1 100
structural engineers design and detail. Provide 86 x 19mm spotted gum decking (Standard
& Better Grade) with Buildex® Dec-King® stainless steel self drilling decking screws to
sfl
structure. Decking shall be installed in accordance with Timber Queensland Technical Data RL 2.80
2 800
Sheet 13. Stairs to be in accordance with NCC 3.9.1. Provide spotted gum 50mm Handrail
Ground floor to have selected 316 stainless steel offset brackets, handrail to comply with NCC 3.9.1. Store
Undercroft storage area with concrete slab to be in accordance with structural engineers
design and detail. Provide fall away from external walls.
Timber framed balustrade in accordance with NCC 3.9.1. with 138 x 42mm h3 treated
primed rails & 66 x 42mm h3 treated primed cross braces. Balustrade to have aluminium
mesh inset panels to feature timber structure. Balustrade to be a min. 1000mm high above
finished floor level.
Bushmans T6500 (30 000L) water tank to be semi in ground max. depth 750mm. tank to
have washed river sandbase and compacted with a plate compactor, to provide a firm level
base. Tank to be installed in accordance with tank manufacturers specifications.
A B C D
Section A
A 1:50
/Users/benthornton/Docs/Cadfiles/1901 - Seeto/Archicad/23072020/1901.pln
sbt designs pty ltd t/a
Skale Building Design builder Chris Fletcher
Director / Builder
project Residence lot no. 9 H Revised Construction issue 20/8/20
project number
Mobile: 0412 025 657 Squire Development Group Pty Ltd
for Dereke & Melanie Seeto plan no. 99140 G Revised Construction issue 23/7/20
1901
skale
0412 743 408 F Revised Construction issue 9/7/20
skale.com.au 71 Noosa River Drive drawn BT
E Revised BA issue 29/6/20
drawing number
building design
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at Noosa North Shore scale (A2) 1:50 Rev Details Date 3.1/1 H © Skale Building Design