Log in to see the plans as drawn¿ play your part - print on recycled paper 2.5m 2 1.5 1 0.5
PV solar system to be in accordance with specialist contractors design and
detail with no penetration fixing clamps to roof sheet.
C D E F G
1 900 10 470 3 090 5 320
0.42mm COLORBOND® steel BlueScope Lysaght TRIMDEK® roof
sheeting to be fixed in accordance with manufacturers specifications. Roof
framing to be in accordance with structural engineers design and detail.
150 600
600 150
COLORBOND® steel BlueScope Lysaght barge flashing to detail. 230 x
31mm h3 treated primed timber fascia.
Timber framed soffit with 6.0mm Hardiflex sheeting installed in accordance
with manufacturers specifications.
2 710
Master suite Dressing Ensuite 1 Bedroom 2 Bathroom 1 Bedroom 3 Timber framed wall to be in accordance with structural engineers design
and detail. Provide 180mm Scyon Linea weatherboard cladding with
aluminium corners installed in accordance with manufacturers
specifications.s.
sfl
RL 5.86
350
350
Timber framed soffit with 6.0mm Hardiflex sheeting installed in accordance
with manufacturers specifications.
1 610
2 710
Hallway Bedroom 6 Selected floor tiles to be installed non-shrink grout bedding. Floor tiles to be
installed with flexible adhesive and provide fall to waste outlet. Structural
flooring to have setdown for wet area to allow for tile bedding layer to
1 100
achieve fall. Floor to have Emer-proof Ecoseal waterproofing barrier
installed to entire floor and wall junctions in accordance with NCC 3.8.1.
sfl sfl
RL 2.80 RL 2.80
100 x 16mm H4 treated hwd paling undercroft screening with H4 treated
2 050
hwd posts and rails. Screening to have palings spaced with 75mm gap and
palings to each side of rails offset.
100 x 16mm H4 treated hwd paling undercroft screening with H4 treated
hwd posts and rails. Screening to have palings spaced with 75mm gap and
palings to each side of rails offset. Battened screening with 2x swing gates
for boat store access.
C D E F G
Section A
A 1:50
/Users/benthornton/Docs/Cadfiles/1901 - Seeto/Archicad/23072020/1901.pln
sbt designs pty ltd t/a
Skale Building Design builder Chris Fletcher
Director / Builder
project Residence lot no. 9 H Revised Construction issue 20/8/20
project number
Mobile: 0412 025 657 Squire Development Group Pty Ltd
for Dereke & Melanie Seeto plan no. 99140 G Revised Construction issue 23/7/20
1901
skale
0412 743 408 F Revised Construction issue 9/7/20
skale.com.au 71 Noosa River Drive drawn BT
E Revised BA issue 29/6/20
drawing number
building design
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at Noosa North Shore scale (A2) 1:50 Rev Details Date 3.1/2 H © Skale Building Design