                                              Feature                        Details
                                              Disposal method                Trenches with Ø100 slotted pipe
                     Disposal Area            Required disposal area         A = Q/DLR = 60 m2 + equivalent reserve area
                                              Install as                     6 trenches x (0.6m wide x 17m long) = 61 m2

              The design of the system is presented in Appendix A.
              The Treatment Plant Approval is presented in Appendix B.

              General requirements and notes
                 • Flow meter to be installed on pump main between OSSF and LAA
                 • 100% reserve area to be kept clear of permanent structures
                 • Deep rip base of trenches and spread gypsum at 1kg/m2
                 • Grass is to be established in the land application area, and mown regularly
                 • Stormwater should not traverse the land application area. Construct a stormwater diversion
                      upslope
                 • General access to the land application area by pedestrians, vehicles and animals is to be
                      generally excluded
                 • Install at least 2x ‘effluent reuse’ warning signs around land application area
                 • The treatment plant is to be installed, operated and serviced in accordance with manufacture
                      specifications
                 • The land application area has been designed based on a daily wastewater volume in accordance
                      with AS1547. Any exceedance of this design volume may have adverse effects on the land
                      application area


              3.3      Effluent Quality
              Table 5 below presents the effluent standards produced by approved wastewater treatment systems
              with subsurface disposal, as per AS1546.3:2017 Secondary Treatment Systems.

              Table 5: Effluent Quality
                                                                   Secondary Effluent              Advanced Secondary Effluent
                               Parameter
                                                            90% of samples       Maximum           90% of samples           Maximum
                                   BOD5                         < 20 mg/L         30 mg/L             < 10 mg/L              20 mg/L
                                    TSS                         < 30 mg/L         45 mg/L             < 10 mg/L              20 mg/L

              The proposed treatment plant has approvals for Advanced Secondary effluent.




              Site and Soil Evaluation                                          Proposed Cabins - 486 Tablelands Road, Cooran Qld 4569
              Taylor Environmental (Australia) Pty Ltd                                                                     Page 7 of 22



Document Set ID: 23040840
Version: 1, Version Date: 31/05/2024
Log in to download the original file

Referenced Doc - Effluent - MCU24_0071.pdf · 4.0 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.