14. Secure bicycle racks shall be provided on site to accommodate a minimum of 3 bicycles. The proposed
bicycle racks shall be identified on the landscaping plans and shall be located to the reasonable
satisfaction of the Manager Land Use.
15. The proposed development shall not exceed a maximum building height of 8 metres and 2 storeys above
natural ground level.
16. A verification survey of the building is to be carried out by a Licensed Surveyor and a certificate lodged
with Council at completion of work confirming compliance with the maximum allowable building height as
required by either the conditions of approval or the Planning Scheme.
17. Security in the form of a cash bond or trading bank guarantee to the sum of $15,000 must be submitted,
to secure performance of all conditions of this approval, prior to the issue of a Development Permit for
Operational Works. The cash bond or trading bank guarantee will be returned on performance of the
conditions of approval less any costs incurred by Council in respect of enforcing performance of this
permit.
18. The Development Permit for a material change of use of premises lapses if the use has not happened by
21 June 2011, unless an application to extend the currency is approved by Council.
19. The requirements of this development approval are to be effected, prior to the use of the premises.
Council reserves the right to call upon the bond or guaranteed sum referred to in this approval to effect
compliance with conditions.
Land Development
Vehicle Access
20. A vehicular access driveway to serve the development shall be constructed from the David Low Way
frontage of the site with a maximum width of 5.5m.
21. The driveway shall be designed and constructed to Council’s design standards and to grades that prevent
vehicles from scraping and/or bottoming whilst also allowing pedestrians movements along the footpath
without any step or level difference. Should any driveways be constructed to grades that do not comply
with AS/NZS 2890.1-2004, Council will require that the driveway be removed and reconstructed to levels
that do comply.
Please note, a step between the driveway and the footpath shall be avoided, as it is preferred to have the
footpath continue at a constant grade to minimise the potential for pedestrians to trip or fall.
22. The vehicle access driveway shall be designed and constructed to provide the required vertical
clearances to the existing water mains and other services located in the David Low Way road reserve in
accordance with Council standards or the relevant authorities guidelines. The levels of the existing
services and the clearances to the proposed driveway shall be clearly shown on any plans submitted for
Operational Works approval.
23. To ensure pedestrian safety between vehicles exiting the site and pedestrians on the footpath, the
driveway and any associated fencing or vegetation near the driveway shall comply with the minimum sight
line requirements as defined in AS2890.1, section 3.2.4. The applicant shall demonstrate compliance by
illustrating these sight lines on the plans submitted for both Operational Works approval and Building
Works approval.
24. All vehicles shall enter and leave the site in a forward direction.
Car Parking
25. Carparking shall be provided within the site as shown on the submitted drawing number 010207-10
prepared by Saint Consulting Engineers, except as modified herein.
26. A minimum of 7 uncovered carpark spaces shall be provided on site, including 1 clearly defined disabled
carpark space. The carparking layout on the southern side of the site shall be revised to provide 3
carspaces and a turning bay. The landscaped setback of the carparking area to David Low Way shall be a
minimum of 2.0m for the full frontage.
27. The carparking area shall be designed to comply with the provisions of AS/NZS 2890.1-2004 for user
class 3 with allowance for vehicles to enter and leave the site in a forward gear and with a minimum head
clearance (headroom) at any point of 2.2m.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@8c06eccd\@[email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Decision Notice - 010.2006.00000718.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 239 KB (small file)
- File type
No other editions are linked here.