Council archive · source document
07/2104 - Response to Information Request [As Published] · 142007.2104
7.0 LIMITATIONS: Field Testing Limitations The soil profiles reported in our Log Section should be representative of the soil conditions over this site. In some cases soil conditions may change dramatically over short distances, therefore exploration programs may not locate all variations. If site excavations reveal soil conditions that are different from those shown in the attached log sections we must be immediately notified. Changes to the site classification and/or footing design may be necessary. Previous Excavations The recommendations contained in this report have not taken into consideration the long term effects of any previous, current or potential subsurface excavation mining or potential slope instability problems. If a slope stability assessment is required for this allotment we can arrange for this to be done, but that type of report is beyond the scope of our commission and fees in this report... -.-- - Client Supplied Information In writing this report we have considered all the information supplied to us by the client. Should the client or his agent have omitted to supply us with relevant information our report may be irrelevant and / or inappropriate. We do not take responsibility for the consequences in such cases and we will make an additional charge if as a result, more testing or re-writing of the report is necessary. General Recommendations for Builders/Owners: Underground Services Where structures are built over uncontrolled fill, services will need to be supported so that settlement of this fill does not cause them damage or cause incorrect alignment. Plumbing Arrange plumbing fixtures so that the slab and beam penetrations are kept to a minimum and where necessary sleeved to allow for movement with 40mm thick closed cell polythene or similar material. Where the penetration is within 150mm of the base of a beam or footing, the depth of this footing element should be deepened by approximately twice the diameter of the penetration. All plumbing and drainage must comply with the requirements of the National Plumbing and Drainage Code. Drainage The ground surrounding the building site must be graded and drained so that water is shed away from the house area in all directions. Particular attention should be given to all drainage and plumbing trenches so that they do not introduce water to the foundation soil, and destabilise the footings. Correct drainage is an essential part of our recommendations and design. If the site is not prepared correctly, excessive soil moisture may accumulate in some areas, which may lead to wall and/or floor movements. Roof water should be diverted away for the building as soon as the roof is installed. Where building delays occur, temporary downpipes may be necessary. Bracing for Wind Forces Unless noted, we do not detail slab thickenings or pad footings to conform to wind bracing. Where a bracing wall is to be bolted to a slab, 40mm bottom concrete cover attained for a radius of 150mm is required around the bolts unless noted by other consultants. Inspections: We require 24 hours notice if you require engineers site inspections. Inspections can be booked between 8.30am and 4.30pm Monday to Friday by telephoning 07 5447 5544. Site Classification: The site classification is calculated in accordance with the "AS2870-1996 Residential slabs and footings-Construction” and relates to the estimation of Ys, “The characteristic surface movement’ within reactive soil profiles. The limits used for this classification are as follows; [Predicted Surface Movement _] Class | Ys = <=20mm $s Slight Ys = >20 - 40mm M Moderate Ys = >40 ~ 70mm H High Ys => 70mm E Extreme Problem sites Pp Problem Foundation Maintenance and Owners Responsibilities Trees and dense shrubs must be kept well away from the building. In all types of soil conditions, if an automatic watering system irrigates within 2.5 meters of a footing, instability problems may occur. Water should not be allowed to pond on the ground near the building. SCG CONSULTING ENGINEERS 5 SCG Ref: 17003(S)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2104 - Response to Information Request [As Published]Related documentApplication case desk ↗
About this file
- File size
- 498 KB (small file)
- File type
No other editions are linked here.