07/2104 - Response to Information Request [As Published] · 142007.2104
Where site drainage and landscaping does not conform to the specifications of AS 2870-1996 and CSIRO information Service Sheet BTF 18 (2003) significant damage to the building can be expected. A single copy of this document is issued with the original issue of this report. Please consult your builder or contact this office to obtain a copy. 6.0 FOOTING AND SLAB SPECIFICATIONS: Footing Details: All footings must be founded a minimum of 300mm into NATURAL MEDIUM DENSE SILTY SANDS _ . (shaded. on.the-attached log sections): Dimensions ‘and reinforcement fequiréménts are detailed in the following footing plan and cross-sections. Where the founding level is deep or is covered by the introduction of fill the footings are to be increased in depth to reach the level. Alternatively the footings can be supported on backhoe dug or drilled piers founded at or below the founding level. Refer to this office for details. Where unexcavatable rock is encountered at depths shallower than the founding level, the strip footing (non-retaining) depth may be reduced accordingly to a minimum of 150mm providing the footing is founded a minimum of 100mm into un-weathered or un-disturbed rock. Additional reinforcement shall be provided in the footing at the rock/soil interface, refer to attached details. Backhoe Piers Supporting the Footings: Where the NATURAL MEDIUM DENSE SILTY SANDS is deep or to be covered by fill the footings can be supported on backhoe piers founded at a minimum of 300mm into the NATURAL MEDIUM DENSE SILTY SANDS. These backhoe piers must be full trench width, 1000mm long and be at a maximum spacing of 3000mm center to center. Drilled Piers Supporting the Footings: Where the NATURAL MEDIUM DENSE SILTY SANDS is deep or to be covered by fill the footings can be supported on 350mm diameter drilled piers founded at a minimum of 300mm into the NATURAL MEDIUM DENSE SILTY SANDS. , Where drilling piers is not practical the footings can be supported on backhoe piers (see cross-section ). Where unexcavatable rock is encountered at depths shallower the founding level the piers shalt be augered a minimum of 100mm into un-weathered or un-disturbed rock. Drilled Pier Reinforcement: [Pier Depthmm | Perimeter Piers | Slab Piers | up to 1500 None required none required 1500-2500 2xN12bars none required 2500-4000 4xN142bars 2xN12bars 4000-6000 6xN12 bars 4xN12bars Floor Slab Details: We recommend reinforcing the floor slab as shown with SL82 slab fabric and the thickenings as specified. Where the foundation level of these thickenings is below prepared pad level, it may be advantageous to excavate them at the same time as the perimeter footing. Where the beams intersect the perimeter footing blockbase, their base must be graded down to the footing base level, 3 x N12 bars must be cogged into the footing, and lapped 500 with the beams trench mesh. Refer to the attached details. SCG CONSULTING ENGINEERS 3 SCG Ref: 17003(S)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2104 - Response to Information Request [As Published]Related documentApplication case desk ↗
About this file
- File size
- 498 KB (small file)
- File type
No other editions are linked here.