roof or balcony overhang must remain clear of the easement and a minimum of 1.0 metre
clear of the barrel of the sewer pipe.
56. Written approval to enter and construct on the road reserve must be provided from Sunshine
Coast Regional Council. This must be submitted with lodgment of the associated development
application for Operational Works.
57. A Unitywater deed of indemnity must be completed by the property owners. It must be signed
by all property owners and the signed original submitted to Unitywater with lodgement of the
Operational Works application.
58. Details of building and deck footings located within 1.5 metres of the sewer pipe must be
submitted with lodgement of the Operational Works application. Drawings must show footings
extending below the zone of influence of the sewer.
59. Operational Works plans must comply with Unitywater design standards including;
59.1. Additional fill provided over the sewer to ensure a minimum 450mm cover over the top
of the sewer pipe.
59.2. Sewer pipe class to be uPVC PN12.
59.3. Provision of a150mm diameter stub out of MH 6/1 to cater for future upstream mains
relocation.
59.4. Survey accurate levels of downstream invert of existing MH3/1 and level of existing pipe
at the proposed location of MH 7/1.
59.5. Details of the proposed retaining wall including foundations extending below the zone of
influence of the sewer.
60. Construction works undertaken in the vicinity of Unitywater water supply or sewerage
infrastructure must not adversely affect the integrity of the infrastructure. All costs associated
with repair, replacement or alteration of infrastructure must be met by the applicant
5 REFERRAL AGENCY CONDITIONS
Reason for Referral Type Referral Agency Agency Address
Referral
Land in or near a Advice Department of Ecoaccess Customer Service Unit
conservation Environment and PO Box 15155
estate Resource Management CITY EAST QLD 4002
A copy of any referral agency conditions is attached.
6 APPROVED PLANS/DOCUMENTS
The approved plans and / or documents for this development approval are listed in the following
table:
Approved Plans
Plan / Document No. Issue. Plan / Document Name Date
0907 -DA100 A Site Plan - Teeland Architects May 2010
0907 -DA101 A Ground Floor Plan - Teeland Architects May 2010
0907 -DA102 A Upper Floor Plan - Teeland Architects May 2010
0907 –DA201 A North Elevation - Teeland Architects May 2010
0907 –DA202 A South Elevation - Teeland Architects May 2010
0907 –DA203 A East Elevation - Teeland Architects May 2010
0907 –DA204 A West Elevation - Teeland Architects May 2010
Page 9 of 19
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED SPA Decision Notice - 010.2010.00000871.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 859 KB (small file)
- File type
No other editions are linked here.