Skip to the record
Accept no substitutions.

Council archive · source document

SUPERSEDED SPA Decision Notice - 010.2010.00000871.001 [As Published] · 132010.871

of 19

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

                                                                                         2010/871




      In this regard a DXF/DWG file on GDA94 zone 56 grid of the proposed cadastre layout is to be
      submitted in conjunction with any application for Operational Works.
43.   Digital detailed designs including drawings, calculations, specifications and a schedule of
      works, must be submitted with any application for a Development Permit for Operational
      Works in respect of roadworks and stormwater drainage works. The design must be in
      accordance with Council’s Planning Scheme Policy PSP05 – Engineering Design Standards –
      Roads, Drainage and Earthworks. To avoid conflict with underground pipes or services, all
      existing and proposed services required by the development must be shown on the plans.
44.   To facilitate production of As Constructed drawings it is suggested that all design drawings are
      submitted in the Asset Design and As Constructed (ADAC) digital format. (Guidelines on the
      use of ADAC are available at www.adac.com.au).
45.   A construction management plan/strategy to ensure no damage occurs to Council services or
      roads must be prepared by a suitably qualified Registered Professional Engineer and
      submitted to Council in conjunction with any application for Operational Works.
46.   Any damage caused to any public utility during the course of construction must be repaired to
      Council’s standards and at no cost to Council.
47.   Any alteration of any public utility or other facilities necessitated by the development of the
      land or associated construction works external to the site must be at no cost to Council.
48.   The transportation of all materials to and from the site must be undertaken in a manner such
      that no particle matter escapes onto a public road. All vehicles carrying materials either to or
      from the site must be covered to prevent materials including dust being windblown from the
      vehicle.
49.   As Constructed drawings and data must be certified by a qualified experienced Civil Engineer
      for design intent, and a Licensed Surveyor must certify the cadastre and the location, level and
      type of all services and structures. All of which must be submitted to Council for checking and
      for Council’s records.
      The data must fully detail levels for all engineering works including but not limited to drainage
      structures, finished ground levels and pavement surface levels. The data must be submitted
      in the Asset Design and As Constructed (ADAC) digital format. (Guidelines on the use of
      ADAC are available at www.adac.com.au).
      Approval of works must not be granted until all As Constructed information has been supplied
      and accepted by Council.
Unitywater
Town Water & Sewerage
50.   Separate 25mm PE water services must be installed to a common lot boundary with
      independent meters installed outside the boundary of the lot in accordance with Unitywater
      Standard Drawing SCW 361.
51.   Water meters must be located on alternative boundaries to electrical pillars.
52.   Buildings and other structures must maintain a minimum clearance of 1.0 metre from the
      nearest part of Unitywater sewer mains, and 1.0 metre from the sewer inspection opening.
53.   Storm water retention systems and gross pollutant traps must maintain a minimum clearance
      of 1.5 metres from Unitywater water supply and sewerage infrastructure.
54.   Proposed tree plantings must maintain a minimum horizontal clearance of 1.0 metre from
      Unitywater water mains and 1.5 metres from Unitywater sewerage mains. Landscaping plants
      within these clearances must be low growing when mature and suitable approved varieties.
55.   A 2.0 metre wide sewer easement, measured from the property boundary, must be provided
      over Unitywater sewers located within the development site. Buildings and structures including

                                                                                      Page 8 of 19

Used in these records

About this file

File size
859 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SUPERSEDED SPA Decision Notice - 010.2010.00000871.001 [As Published].pdf · 859 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.