6.3 RESIDENTIAL BUILDINGS FACADE CONSTRUCTION In addition to the management controls, to achieve the indoor noise levels within the considered habitable areas (refer to Section 5.2), the following minimum facade construction is proposed. Refer to Table 5 for specific locations where each Facade Type applies. Table 6 - Fagade Construction Recommendations Type Glazing Systems Facade Wall A Nominal openable glazing system - Rw33 Masonry construction or Cladded nominally with 6.38mm lam glass and seals | facade (9mm fibre cement sheet) on 90mm timber studs - cavity insulation (e.g. 75mm thick 11kg/m3 glasswool) — min 10mm thick plasterboard internally B Nominal openable glazing system - Rw35 Masonry construction or Cladded nominally with 10.38mm lam glass and facade (9mm fibre cement sheet) acoustic seals on 90mm timber studs - cavity insulation (e.g. 75mm thick 11kg/m3 glasswool) — min 13mm thick Fyrchek plasterboard internally Cc Nominal openable glazing system - Rw37 Masonry construction or Cladded nominally with 10.76mm lam glass and fagade (9mm fibre cement sheet) acoustic seals on 90mm timber studs - cavity insulation (e.g. 75mm thick 11kg/m3 glasswool) — min 2 layers of 13mm thick Fyrchek plasterboard internally In the case where any of the apartments/habitable areas are elevated with the floor exposed to noise from the shopping centre, the floor is assumed to be of concrete construction (nominally 150mm thick). Other construction details may be acceptable but must be reviewed and approved by an acoustic consultant in order to achieve indoor noise levels of finalised building layouts. The minimum roof construction must be of concrete or alternative colorbond with Anticon 145 and plasterboard ceiling with 75mm thick glasswool (11kg/m3) overlay. Where building layouts and locations or habitable areas differ from what has been considered, additional assessment is required. Buildings located further from the loading docks in comparison to the ones considered in this report must be constructed based on Type A construction as a minimum. I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 26
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20200903OBA_R1_Loading_Dock_Operational_Conditions.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.