ORK IS COPYRIGHT AND THE PROPERTY OF ROY K. SAINT PTY. LTO. IT MUST NOT BE COPIED, REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION
EXISTING TO BE RENOVATED NEW EXTENSION
=e _—_
12000
3240 2640 3120 3000 NEW RAMP GRADED @ lin/4 WITH NON-SLIP
FINISH AND HANDRAILS TO 8CA REQUIREMENTS
70 70 70 70 70
3170 530 5020 2930
STAIRS, HANDRAIL & BALLUS TRADE
TO BCA REQUIREMENTS
3
z FFL10.3 5 2
i
3
Deck 3 =
> 2
8 Deck Video Room =
nN
sb S
wo
=
. \_| wee ;
~ a =
ee ] (EXIT)
s , Staff Rom |[ — I =
fiat _ S
8 || Waiting Room Office &
=] ll eZ nN
et Ed ot! it |
Ss — | L AN S
Ss 5 ° FFL9.37 2s
x s Es Unisex tt ; | aes
= & Ol (Beception. —_ — — _ 4 a
>
= T 3 4 Lab 3
ia | esos a ein 2
a ll S
é ll lI
Ss Surgery | i eo Surgery 2 Py
= a a
Feeeee eas a
3 rc)
3 Surgery 3 3
| a-Fa |
os ———$_——» — I
a ll
s ie
2 Jl e _ jj 2
" 2200 - 6590 0 1000 1860 ” PROVIDE ALL NECESSARY XRAY WALL, FLOOR, CEILING & DOOR
TREATMENT AROUND EACH INDIVIDUAL DENTAL SURGERY ROOM
70 70 70 70 70 70 TO CONTAIN XRAY IN ACCORDANCE MTH DENTAL PRACTISE
3250 1400 3000 1000 2930 REQUIREMENTS
12000

PROPOSED UPPER FLOOR PLAN
Scale 1:100 (A3)
e DENOTES HARDWIRED SMOKE DETECTOR
INSTALLED TO BCA REQUIREMENTS

DENOTES ILLUMINATED EXIT SIGN TO BCA

REQUIREMENTS.

[EXIT] FINAL LOCATION AND EXTENT OF EXIT SIGNS TO BE DETERMINED

ON SITE BY BUILDER AND ELECTRICIAN

DEVELOPMENT AREAS

PROPOSED MEDICAL GROSS FLOOR AREA = 1/6 sqr.m.
PROPOSED UPPER DECK GROSS FLOOR AREA = 2/ sqr.m.
PROPOSED LOWER ANCILLARY DWELLING GROSS FLOOR AREA = 50 sqr.m.

PROPOSED LOWER OFFICE GROSS FLOOR AREA = 58 sqr.m.

TOTAL GROSS FLOOR AREA = 245 sqr.m.

 

ALLMAN WINDOWS: All aluminium framed windows and sliding door
units shall be to ASIZ88, shall be to matching design and be supplied mth
@ ™anutocturers guarantee of suitablity for the relevant design mnd speed.

INTERNAL LININGS: Unless stated otherwise, internal linings shal be 10mm
Gyprock. Where required, internal timber framed bracing walls shall be

lined with 6mm Hoardiflex, Wel area walls shall be lined with 6mm

Villoboard. Ceiling battens shall be either 50 x 38 F5 (ar better) pine

or equivalent galvanized steel turning channels. Al to manufacturers
specications.

ROOFING: Selected Colorbond stee! mith sarking and honzonta/ bracing to roof
truss manufacturers specitications.

FASCAS AND GUTTERS: Selected matching Colorband steel to
monutocturers specifications.

EXTERNAL WALLS: Unless stated otherwise, selected facebrick to ASJ700
nth approved brick bes installed ot 300mm maximum centres at oll
Floor fevels and at the 2nd brick course from the top plus at 600mm
max. horizontal and vertical centres in general wall areas. DPC. shall be
built in below each FFL. and wall qpening. Weep holes shall be

at 900mm maximum centres at oll OPCS. Selected waterproof

texture coator concrete render to manuf. spec. to all external surfoces.

ROOF STRUCTURE: Unless stated otherwise, 55 x 70 8 (or better)
battens at 900mm maximum centres fixed to 1/90mm No. 14 lye 17
screw (50mm penetration for Joint Group J04 timber) to engineered
roof trusses. Trusses shall be at 900mm maximum centres and to
monutocturers specifications.

Doors to sanitary compartments without 1200mm clear
space between the back of the door and the closest
obstacle (such as the toilet bow! or hand basin) must
either open outwards, slide or be readily removable
from the outside.

All concrete slabs and footings shall be to structural
engineer's recommendations and in compliance with
AS2870.

Unless stated otherwise, the owner/s and builder shall
agree as to the location, type and quality of all
fittings, fixtures and finishes prior to commencement.

HANDRAIL & BALUSTRADES

BALUSTRADE POSITIONED MIN 865mm ABOVE NOSING OF TREADS.

1m MIN. ABOVE BALCONY,LANDING OR THE LIKE

OPENING IN BALUSTRADES TO BE CONSTRUCTED SO A 125mm SPHERE

IS NOT PERMITTED TO PASS THROUGH & FOR A STAIR THE SPACE TESTED
'S ABOVE THE NOSING.

ALL STAIRS HANDRAILS & BALUSTRADES TO COMPLY WITH

BCA 1996 PART 3.9.1 & 3.9.2

HORIZONTAL STEEL WIRE

DO NOT USE IF DECK HT EXCEEDS 4.0M FROM FINISHED GROUND LEVEL
125x50mm TOP RAIL WITH SUPPORTS @ 1800c/c MAX.

HORIZONTAL STEEL WIRE RAILS @ 80mm c/c MAX
DROPPERS @ 600mm c/c MAX
6m MAX. TO EACH TENSIONING POINT.

 

 

GAG DESIGN

ee = A.B.N. 15.096 410 909

 

/ Saint Consulting

ENGINEERS

 

PROPOSED UPPER PLAN

AT

 

1:100 (A3) ISSUE PRINTED: CADO001

010207-04

 

 

ISSUE DATE REVISION

QOOOOOOOO0O

 

Used in these records

About this file

File size
10.2 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

06_0718 - Response to request for further information [As Published].pdf · 10.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.