HT AND THE P

ERTY OF ROY K. SAINT PTY LTD. IT MUST NOT BE COPIED. REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR

IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION

 

70 70 70
1800 2780

SCREENED AND SECURED COURTYARD

TO OWNERS REQUIREMENTS

COURTYARD

70 ~=—70 70
1500-900 4600

COURTYARD

ee = SS

 

 

70

 

 

900

 

 

Bathroom

 

 

 

Kitchen

 

 

1830

 

 

|

Kitchette E|

 

 

 

 

70

 

 

 

Living Room

&

2920
Entry

 

 

Shee

 

70

3000
concrete footpath

 

Bedroom 1 - Bedroom 2

 

 

 

 

70

 

concrete footpath

LANDING ABO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROPOSED LOWER FLOOR PLAN

Scale 1:100 (43)

DENOTES HARDWIRED SMOKE DETECTOR
INSTALLED TO BCA REQUIREMENTS

DENOTES ILLUMINATED EXIT SIGN TO BCA REQUIREMENTS.
[EXIT] FINAL LOCATION AND EXTENT OF EXIT SIGNS TO BE DETERMINED
ON SITE BY BUILDER AND ELECTRICIAN

CONCRETE STAIRS TO BCA REQUIREMENTS
EXTENT TO BE DETERMINED ON SITE

NEW MASONRY RETAINING WALL TO RETAIN

EDGE OF CARPARK CIVILWORKS — REFER SITE PLAN
FOR DETAILS. Im HIGH HANDRAIL

TO THE TOP OF ALL WALLS

ALUMINIUM WINDOWS: Al aluminium framed mindows and stiding door
units shall be to AS1288, shall be to matching design and be supplied mth
2 ™anutocturers guarantee of suitablity for the relevant design mnd speed.

INTERNAL LININGS: Unless stated othermse, internal linings shall be 10mm
Opprock. Where required, internal timber framed brocing wals shall be
ined with 6mm Hordilex. Wet area walls sholl be lined with bmm
Viloboard. Ceiling battens shall be either 50 x 58 F5 (or better) pine
or equivalent galvanized steel fuming channels. All to manufacturers
specifications,

ROOFING: Selected Colorbond stee/ mith sarking ond horizontal bracing to roof
truss manufacturers specifications.

FASCUS AND GUTTERS: Selected matching Colorbond stee/ to
monvtacturers specifications.

EXTERNAL WALLS: Unless stated otherwise, selected facebrick to ASI700
mith approved brick tes installed at 300mm maximum centres ot oll
oor kevels and at the 2nd brick course from the top plus at 600mm
max. honizontal and vertical centres in genera/ woll areas. DPC. shall be
built in below eoch FFL. and wall opening. Weep holes shall be

at 900mm maximum centres ot ol DP.CS. Selected waterproof

(fexture cootor concrete render to manuf spec. to all external surfoces.

ROOF STRUCTURE: Unless stated otherwise, J5 x 70 F8 (or better)
battens at 900mm maximum centres fired to 1/90mm No. 14 Type 17
screw (50mm penetration for Joint Group JO4 timber) to engineered
root trusses. Trusses shall be at 900mm maninum centres and to
monvtaocturers specifications.

Doors to sanitary compartments without 1200mm clear
space between the back of the door and the closest
obstacle (such as the toilet bow! or hand basin) must
either open outwards, slide or be readily removable
from the outside.

All concrete slabs and footings shall be to structural
engineer's recommendations and in compliance with
AS2870.

Unless stated otherwise, the owner/s and builder shall
agree as to the location, type and quality of all
fittings, fixtures and finishes prior to commencement.

HANDRAIL & BALUSTRADES

BALUSTRADE POSITIONED MIN 865mm ABOVE NOSING OF TREADS.

im MIN. ABOVE BALCONY,LANDING OR THE LIKE

OPENING IN BALUSTRADES TO BE CONSTRUCTED SO A 125mm SPHERE

IS NOT PERMITTED TO PASS THROUGH & FOR A STAIR THE SPACE TESTED
IS ABOVE THE NOSING.

ALL STAIRS HANDRAILS & BALUSTRADES TO COMPLY WITH

BCA 1996 PART 3.9.1 & 3.9.2

HORIZONTAL STEEL WIRE

DO NOT USE IF DECK HT EXCEEDS 4.0M FROM FINISHED GROUND LEVEL
125x50mm TOP RAIL WITH SUPPORTS @ 1800c/c MAX

HORIZONTAL STEEL WIRE RAILS @ 80mm c/c MAX.

DROPPERS @ 600mm c/c MAX

6m MAX. TO EACH TENSIONING POINT.

 

GAG DESIGN

 

REVISION

Saint, Consulting
{ ENGINEERS

* A.B.N, 15.096 410 909

 

MIEAust CPEng Aust.No.29986
RPEQ No. 1476 NPER-3 No.40467
QBSA Lic.No. 16080

1 STANLEY STREET, NAMBOI
INE : (07) 54412233 FAX : (0
[email protected]

 

  

PROPOSED LOWER PLAN

AT

FOR

 

OOOOOOOOO:

1:100 (A3) ISSUE PRINTED: CADO01

010207-05

 

 

ISSUE DATE

 

Used in these records

About this file

File size
10.2 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

06_0718 - Response to request for further information [As Published].pdf · 10.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.