CARPARK AREA
HIGH LEVEL OVERFLOW FROM GPT 9 _|
|
|
ROCLA or FOX BGPCT OR EQUIVALENT UNIT
150¢ UPVC
GRADED @ 1in100
TO DETENTION TANK
water level varies
1506 UPVC
GRADED @ 1in100
FROM CARPARK
5000 LITRE
NON-POTABLE
DETENTION TANK
150¢ UPVC
NOT TO SCALB
100¢ UPVC
LOW FLOW OUTLET GRADED @ 1in100
FROM DETENTION TANK
STORMWATER TANK
SCHEMATIC PLAN
1506 UPVC
HIGH LEVEL OVERFLOW
1
BOUNDARY
DRAINAGE EMT
TO BE CONFIRMED
BY TOWN PLANNER
OVERFLOW DISCHARGE FROM
ROOFWATER STORAGE TANK
NEW 600 SQR
FIELD INLET WITH
GRATED LID
OVER EXISTING PIPE
STORMWATER DRAINAGE NOTES
GENERAL
General: Provide stormwater drains to connect downpipes, surface drains, subsoil
drains and drainage pits to the outlet point or point of connection.
Downpipe connections: Turn up branch pipelines with bends to meet the downpipe,
finishing 50 mm (nominal) above finished ground or pavement level. Seal joints
between downpipes and drains.
Tolerances: Comply with the Pipeline tolerances table. These tolerances are conditional
on falls to outlets being maintained and no part of a pipeline being at less than the
designated gradient.
Pipe Materials
Stormwater pipe to be F.R.C. or U.P.V.C. class SH in accordance with AS3500.3
Connection to kerb to be galvanised RHS in accordance with AS1074 with minimum
coating mass of 500g/sqr.m
Identification
Lay a detectable strip or plastic tape in the trench after pipelaying, testing and initial
backfilling.
Pipe underlay
General: Bed piping on a continuous underlay of bedding material, at least 75 mm
thick after compaction. Grade the underlay evenly to the gradient of the pipeline.
Chases: If necessary, form chases to prevent projections such as sockets a flanges
from bearing on the trench bottom or underlay.
Pipe surrounds
General: Place the material in the pipe surround in layers 200 mm loose thickness,
and compact without damaging or displacing the piping.
Anchor blocks
If eceanaeyy provide anchor blocks which restrain lateral and axial movement of the
pipelines at junctions and changes of grade or direction.
Encasement
General: If necessary, encase the pipeline in concrete at least 150 mm above and
below the pipe, and 150 mm each side or the width of the trench, whichever is the
greater.
Concrete: Grade N20 to AS 1379.
Pipe depth
Provide the following minimum clear depths, measured to the crown of the pipe,
where the pipe passes below the following elements:
- 100 mm below formation level of the avemen kerb or channel.
- 100 mm below the average gradient of the bottom of footings.
- 450 mm below the finished surface of unpaved ground.
Jointing
At junctions of subsoil pipes provide tees, couplings or adaptors to AS 2439.1.
Trench width Minimum 450 mm.
Pipe underlay
General: Grade the trench floor evenly to the gradient of the pipeline. If the trench
floor is rock, correct any irregularities with compacted bedding material. Bed piping
on a continuous underlay of bedding material, at least 75 mm thick after
compaction. Lay the pipe with one line of perforations at the bottom.
Chases: If necessary, form chases to prevent projections such as sockets and flanges
from bearing on the trench bottom or underlay.
Pipe surrounds
General: Place the material in the pipe surround in layers 200 mm loose thickness,
and compact without damaging or displacing the piping.
nee of overlay: .
- To the underside of the bases of overlying structures such as pavements, slabs
and channels.
- To within 150 mm of the finished surface of unpaved or landscaped areas.
ISSUE DATE
GAG DESIGN
Sai
nt. Consulting
ENGINEERS
A.B.N. 15 096 410 909
MiEAust CPEng Aust.No.29986
RPEQ No.1476 NPER-3 No.40467
QBSA Lic.No. 16080
} STANLEY STREET, NAMBOUR QLD. 4560. 4564
PHONE : (07) 54412233 FAX : (07) 54763218
roy@saintconsutting. org
AT
FOR
STORMWATER MANAGEMENT DETAILS
OQOOOO0O0O
= N.T.S. (A3) ISSUE PRINTED: CADO01
inc No.|010207-11
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/0718 - Response to request for further information [As Published]Related documentApplication case desk ↗
About this file
- File size
- 10.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.