Council archive · source document
06/0718 - Response to request for further information [As Published] · 132006.718
Very large file (10.2 MB): the original may take a few minutes to open or download. The page text below is quick to read.
THIS WORK IS COPYRIGHT AND THE PROPERTY OF ROY K SAINT PTY. LTD. IT MUST NOT BE COPIED, REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION NOTES GENERAL : These notes and structural details are to be read FOOTING DIMENSION TABLE in conjunction with the designer's drawings and TOTAL HEIGHT ve specification associated with this project. OF RETAINING 8 BARS FOUNDATION Footings have been designed in accordance 1000 800 NiZ with AS2870-1996 and to be confirmed by foundation 1200 900 N12 investigation report. 1400 1000} N16 All foundations to be confirmed by geotechnical consultant prior to placement of foundation 1600 1100) N16 reinforcement. Minimum safe bearing capacity 1800 1300} N16 for all footings to be 100 kPa. 2000 1400] N20 ENGINEER TO BE CONTACTED IF CONCRETE : (1-50km from coast) WALL HEIGHT EXCEEDS TABLE 1m HIGH HANDRAIL WITH Workmanship and materials shall be in accordance BALUSTRADE FIXED TO TOP with AS 3600-2001. Concrete shall have the OF WALL TO MANUFACTURERS following properties: — DESIGN & SPECIFICATIONS CARPARK Bond beams, Retaining walls:—F’c=20 MPa at 28 x days, 10 nominal SN agg. 200 slump a All concrete shall be moisture cured for (7) days after pouring, by an approved method. REINFORCEMENT Reinforcement grade designated as follows:— ‘R’ Denotes round mild steel bar, Grade 500 "N’ Denotes high yield deformed bar, Grade 500 "SL’ Denotes welded fabric, Grade 500 GEOFABRIC ‘Ww’ Denotes hard drawn deformed wire, Grade 500 MEMBRANE GRAVEL SCREENINGS REFER TABLE MINIMUM CLEAR CONCRETE COVER:— Element | Formed and| Formed and |With earth sheltered exposed to as form location weather/earth| Footings = 65 75 Columns 40 50 75 N12 © 400 CTS 55 INSIDE COVER 7 ~ WATER PROOF SEALANT TO BACK OF WALL = N12 @ 400 HORIZONTAL REINFORCEMENT —+ +H- MINIMUM REINFORCEMENT LAPS:— Member] Lap Member | Lap 200 SERIES FULLY CORE FILLED "H’ PATTERN BLOCKWORK —, - 100 AGG. DRAIN N12 350 N32 2125 RETAINING WALL WITH DISCHARGING TO GRATED PIT N16 600 SL8T™ | 650 CLEANOUT AT BASE 3 WITH FROG FLAP OUTLET N20 800 MESH | 425 end (MIN 0.5% GRADE) N24 1200 225 side 7 \ Lt N28 1650 Wea RETAINING WALL HEIGHT 2m MAX. BLOCKWORK All workmanship and materials shall comply to AS 3700-1998 "Masonry Structures Code” External blockwork face to be coated with a suitable 7 ” waterproof coating in accordance with AS 2311. 250 'V’ BARS © 400 CTS wots oh Mortar types shall comply with AS 3700-1998 and amendments. Mortar types shall be :— ‘V’ STARTER BARS LOCATION IN BUILDING MORTAR MIX @ 400 CTS Cement Lime Sand REFER TABLE Damp proof course and B — REFER TABLE load bearing walls 1 1.0 6.0 + Non-load bearing ext. wall 1 1.0 9.0 Non—load bearing int. walls} 1 1.0 9.0 SITE PREPARATION Br Ng feria in eect MASONRY RETAINING WALL DETAIL for commercial and residential developments. N.T.S. = RETAINING WALL DETAILS GAG DESIGN _N.T.S.(A3) | ISSUE PRINTED: CAD001 MIEAust CPEng Aust.No.29986 | . } . (Saint, Consulting sancis\“- a —~ i. OQOOOOOOO0O ENGINEERS + STANLEY STREET, NAMBOUR QLD. 4560. 4564 ‘ 7 + = ABN. 15096 410 909 PHONE : (07) 54412233 FAX : (07) 54763218 IRAWING N a ISSUE __ DATE REVISION [email protected] FOR
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/0718 - Response to request for further information [As Published]Related documentApplication case desk ↗
About this file
- File size
- 10.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.